首页> 外文期刊>Journal of forensic sciences. >The effect of breath freshener strips on two types of breath alcohol testing instruments.
【24h】

The effect of breath freshener strips on two types of breath alcohol testing instruments.

机译:口气清新剂条对两种类型的酒精测试仪器的影响。

获取原文
获取原文并翻译 | 示例
           

摘要

The potential for breath freshener strips to interfere with the accuracy of a breath alcohol test was studied. Twelve varieties of breath freshener strips from five manufacturers were examined. Breath tests were conducted using the infrared based BAC DataMaster or the fuel cell based Alco-Sensor IV-XL, 30 and 150 seconds after placing a breath strip on the tongue. No effect was observed using the Alco-Sensor system. Some of the strips gave a small reading at 30 seconds (less than or equal to 0.010 g/210 L apparent alcohol) using the DataMaster. Readings on the DataMaster returned to zero by the 150 second test. A proper pre-test observation and deprivation period should prevent any interference from breath freshener strips on breath alcohol testing.
机译:研究了口气清新剂带干扰口气酒精测试准确性的可能性。检查了来自五个制造商的十二种呼吸清新剂带。在将呼吸带放在舌头上30和150秒后,使用基于红外线的BAC DataMaster或基于燃料电池的Alco-Sensor IV-XL进行呼吸测试。使用Alco-Sensor系统未观察到任何影响。使用DataMaster在30秒内某些条带的读数很小(小于或等于0.010 g / 210 L表观酒精)。经过150秒的测试,DataMaster上的读数恢复为零。正确的测试前观察和禁食期应防止呼吸清新剂带对呼吸酒精测试造成任何干扰。