...
首页> 外文期刊>Journal of experimental psychology. human perception and performance >Calibration Is Action Specific But Perturbation of Perceptual Units Is Not
【24h】

Calibration Is Action Specific But Perturbation of Perceptual Units Is Not

机译:校准是特定于动作的,但不是对感知单位的干扰

获取原文
获取原文并翻译 | 示例
           

摘要

G. P. Bingham and C. C. Pagano (1998, The necessity of a perception/action approach to definite distance perception: Monocular distance perception to guide reaching. Journal of Experimental Psychology: Human Perception and Performance, 24, 145-168) argued that metric space perception should be investigated using relevant action measures because calibration is an intrinsic component of perception/action that yields accurate targeted actions. They described calibration as a mapping from embodied units of perception to embodied units of action. This mapping theory yields a number of predictions. We tested two of them. The first prediction is that calibration should be action specific because what is calibrated is a mapping from perceptual units to a unit of action. Thus, calibration does not generalize to other actions. This prediction is consistent with the "action-specific approach" to calibration (D. R. Proffitt, 2008, An action specific approach to spatial perception. In R. L. Klatzky, B. MacWhinney, & M. Behrmann (Eds.), Embodiment, ego-space and action (pp. 179-202). New York, NY: Psychology Press.). The second prediction is that a change in perceptual units should generalize to all relevant actions that are guided using that perceptual information. The same perceptual units can be mapped to different actions. Change in the unit affects all relevant actions. This prediction is consistent with the "general purpose perception approach" (J. M. Loomis & J. W. Philbeck, 2008, Measuring spatial perception with spatial updating and action. In R. L. Klatzky, B. MacWhinney, & M. Behrmann (Eds.), Embodiment, ego-space and action (pp. 1-43). New York, NY: Psychology Press). In Experiment 1, two targeted actions, throwing and extended reaching were tested to determine if they were comparable in precision and in response to distorted calibration. They were. Comparing these actions, the first prediction was tested in Experiment 2 and confirmed. The second prediction was tested in Experiment 3 and confirmed. The action-specific and general purpose perception approaches each fail to predict the alternative results predicted by the other. Both sets of results were predicted by the mapping among embodied units theory of calibration.
机译:GP Bingham和CC Pagano(1998,确定距离感知的感知/行动方法的必要性:单眼距离感知指导到达。实验心理学杂志:人类感知与性能,24,145-168)认为,度量空间感知应该由于校准是感知/动作的内在组成部分,可以产生准确的针对性动作,因此需要使用相关的动作措施进行调查。他们将校准描述为从感知的具体单位到行动的具体单位的映射。这种映射理论产生了许多预测。我们测试了其中两个。第一个预测是,校准应该是特定于动作的,因为被校准的是从感知单位到动作单位的映射。因此,校准不会推广到其他动作。该预测与校准的“特定于动作的方法”相一致(DR Proffitt,2008,一种针对空间感知的特定于动作的方法。在RL Klatzky,B.MacWhinney和M.Behrmann(编辑),实施例,自我空间(第179-202页),纽约,纽约:心理学出版社)。第二个预测是,感知单位的变化应推广到所有使用该感知信息指导的相关动作。相同的感知单位可以映射到不同的动作。单位变更会影响所有相关动作。该预测与“通用目的感知方法”(JM Loomis和JW Philbeck,2008,通过空间更新和动作来测量空间感知)相一致。在RL Klatzky,B.MacWhinney和M.Behrmann(编辑),实施例中,自我-space and action(pp.1-43)。纽约,纽约:心理学出版社)。在实验1中,测试了两个有针对性的动作,即投掷和伸展动作,以确定它们在精度和校正失真方面是否具有可比性。他们是。比较这些动作,在实验2中测试并确认了第一个预测。第二个预测在实验3中进行了测试并得到确认。特定于动作和通用目的的感知方法均无法预测彼此预测的替代结果。两组结果都是通过标定内含单位理论之间的映射来预测的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号