A comparative study of the fatigue resistance of engine-driven nickel-titanium endodontic instruments was performed, aiming to access the influence of the cutting flute design and of the size of the files that reach the working length in curved canal shaping. Geometrical conditions similar to those found in practice were used. Series 29 #5 ProFile, together with #6 and #8 Quantec instruments, were tested in artificial canals with a 45-degree angle of curvature and 5-mm radius of curvature. It was observed that the size of the instrument, which determines the maximum strain amplitude during cyclic deformation, is the most important factor controlling fatigue resistance. The effect of heat sterilization on the fatigue resistance of the instruments was also examined. The results obtained indicate that the application of five sterilization procedures in dry heat increases the average number of cycles to failure of unused instruments by approximately 70%.
机译:对发动机驱动的镍钛牙髓器械的抗疲劳性进行了比较研究,目的是了解切削槽设计的影响以及在弯曲管成形过程中达到工作长度的锉刀尺寸的影响。使用与实际发现的几何条件相似的几何条件。 29系列#5 ProFile与#6和#8 Quantec仪器一起在具有45度曲率角和5 mm曲率半径的人工运河中进行了测试。据观察,确定循环变形过程中最大应变幅度的仪器尺寸是控制疲劳强度的最重要因素。还检查了加热灭菌对器械疲劳强度的影响。获得的结果表明,在干热环境中应用五种灭菌程序可使未使用器械失效的平均循环次数增加约70%。