首页> 外文期刊>Journal of Endodontics: Official Journal of American Association of Endodontists >Effect of Cyclic Fatigue on Static Fracture Loads in ProTaper Nickel-Titanium Rotary Instruments.
【24h】

Effect of Cyclic Fatigue on Static Fracture Loads in ProTaper Nickel-Titanium Rotary Instruments.

机译:ProTaper镍钛旋转仪器中循环疲劳对静态断裂载荷的影响。

获取原文
获取原文并翻译 | 示例
           

摘要

The aim of the present study was to evaluate static fracture loads of ProTaper Nickel-Titanium instruments that had been subjected to various degrees of cyclic fatigue. Torque and angle at failure of new instruments and instruments that had been stressed to 30, 60, or 90% of their cyclic fatigue rotations in a simulated canal (90 degrees and 5 mm radius) were tested according to ISO 3630-1. With unused ProTaper instruments, resistance to cyclic fatigue decreased with diameter increase and ranged from 158 to 450 rotations. Torque at failure ranged from 0.5 to 2.1 Ncm and showed a strong linear relationship to instrument diameter (r = 0.9) while angle at failure was weakly related to diameter (r = 0.46). Cyclic prestressing significantly reduced torsional resistance in finishing files, while shaping files were largely unaffected. In conclusion, build-up of tension within NiTi rotary instruments depends on instrument diameter. Clinically, larger instruments that have been subjected to some cyclic fatigue should be used with great care or discarded.
机译:本研究的目的是评估ProTaper镍钛仪器承受的不同程度的循环疲劳的静态断裂载荷。根据ISO 3630-1测试了在模拟渠道(90度和5 mm半径)中承受了其周期性疲劳旋转的30%,60%或90%的新器械损坏时的扭矩和角度。使用未使用的ProTaper仪器,随着直径的增加,对循环疲劳的抵抗力会降低,范围为158至450转。破坏时的扭矩在0.5到2.1 Ncm之间,与器械直径呈强线性关系(r = 0.9),而破坏时的角度与直径呈弱关系(r = 0.46)。循环预应力显着降低了精加工锉的抗扭强度,而成形锉则基本不受影响。总之,NiTi旋转仪器内部张力的积累取决于仪器直径。在临床上,应小心使用或丢弃已遭受某些周期性疲劳的较大器械。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号