The purpose of this study was to compare the effects of two engine-driven, nickel-titanium instrument systems with hand files in the final shape of slight and moderately curved canals. A total of 72 mesial roots of extracted human mandibular molars were divided into three groups: ProFile .04 taper, Pow-R rotary systems, and Flex-R hand-filing technique. The roots were mounted and cross-sectioned at two different horizontal levels using a modified Bramante technique. Pre- and postinstrumented cross-sectional roots were imaged, recorded, and computer analyzed. Results showed that, at the middle third, in almost all groups, there was a tendency of cutting more toward the mesial side with only one exception: Pow-R cut more to the distal side (danger zone) (p < 0.02). At the apical third, Flex-R (p < 0.03) and ProFile (0.001) transported to the mesial side (danger zone) when the curvature increased. When the three techniques were compared analyzing each side and considering the two groups of curvature, at the middle third in the moderately curved-canal group, Flex-R cut statistically more than Pow-R toward the lingual side. The other comparisons showed no statistically significant difference. When the techniques were compared in relation with the degree of curvature, in the apical third, ProFile .04 cut statistically more toward the mesial side in the moderately curved canal group than in the slightly curved canal group. The other comparisons showed no statistically significant difference. Canal preparation time was shorter with hand instrumentation (p < .05) in a few instances.
机译:这项研究的目的是比较两种发动机驱动的镍钛器械系统与带有锉刀的器械的效果,这些器械的最终形状为中度弯曲的管道。总共提取的人类下颌臼齿的72个近中根被分为三组:ProFile .04锥度,Pow-R旋转系统和Flex-R手动归档技术。使用改良的Bramante技术将根部安装在两个不同的水平位置并进行横截面剖切。将仪器前和仪器后的横截面根部成像,记录并进行计算机分析。结果显示,在几乎所有组中,中间三分之一组都有向内侧面切更多的趋势,只有一个例外:Pow-R向远端切更多(危险区)(p <0.02)。在根尖处,曲率增加时,Flex-R(p <0.03)和ProFile(0.001)传输到内侧(危险区域)。当比较这三种技术以分析两侧并考虑两组曲率时,在中度弯曲管组的中间三分之一处,Flex-R在统计上比舌侧切开的程度要多于Pow-R。其他比较显示无统计学显着差异。当比较弯曲度方面的技术时,在根尖的第三根中,ProFile .04在统计上比中度弯曲的根管组更向内侧切入。其他比较显示无统计学显着差异。在少数情况下,使用手动器械进行运河准备的时间较短(p <.05)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号