首页> 外文期刊>Journal of endovascular therapy: an official journal of the International Society of Endovascular Specialists >Side-branched modular endograft system for thoracoabdominal aortic aneurysm repair.
【24h】

Side-branched modular endograft system for thoracoabdominal aortic aneurysm repair.

机译:侧支模块化模块化移植系统用于胸腹主动脉瘤修复。

获取原文
获取原文并翻译 | 示例
       

摘要

Purpose: To describe a side-branched modular endograft system that provides adequate visceral artery perfusion with perfect seal during thoracoabdominal aortic aneurysm (TAAA) repair. Case Report: A 76-year-old man with a 57-mm TAAA involving the celiac artery was treated with a customized Talent endograft consisting of a 46-mm x 18-cm stented main body and a 6-mm x 30-mm nonstented Dacron side branch. The graft was delivered through a surgical exposure of the left common femoral artery. A 6-mm x 10-cm Hemobahn stent-graft was introduced in the 30-mm side branch from the aorta to the celiac trunk through a long 8-F sheath via the left brachial artery. The patient recovered uneventfully except for a mild reactive inflammatory syndrome. Postoperative computed tomography demonstrated total exclusion of the TAAA sac and good antegrade perfusion of the celiac and superior mesenteric arteries, which has been maintained at the 6-month follow-up. Conclusions: Endovascular treatment of TAAA is feasible with further technical refinements of available technology.
机译:目的:描述一种侧支模块式内移植系统,该系统在胸腹主动脉瘤(TAAA)修复期间可提供足够的内脏动脉灌注和完美的密封。病例报告:一名76岁的男子,其腹腔动脉受累的TAAA值为57毫米,接受了定制的Talent内植体治疗,该植体由46毫米x 18厘米的支架主体和6毫米x 30毫米的非支架组成涤纶侧支。通过外科手术暴露左股总动脉进行移植。将一条6毫米x 10厘米的Hemobahn支架移植物通过一条长长的8-F鞘管通过左臂动脉从主动脉到腹腔干引入30毫米的侧支中。除轻度反应性炎症综合症外,患者康复良好。术后计算机断层扫描显示完全排除了TAAA囊,并对腹腔和肠系膜上动脉进行了良好的顺行灌注,并在6个月的随访中得以维持。结论:通过现有技术的进一步技术改进,TAAA的血管内治疗是可行的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号