首页> 外文期刊>Journal of endovascular therapy: an official journal of the International Society of Endovascular Specialists >A new mechanical device for declotting of hemodialysis access grafts: first clinical experience.
【24h】

A new mechanical device for declotting of hemodialysis access grafts: first clinical experience.

机译:一种用于血液透析通路移植物凝血的新型机械设备:首次临床经验。

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose: To review the early clinical experience with a new mechanical thrombectomy device for declotting polytetrafluoroethylene (PTFE) hemodialysis access (HDA) grafts.Methods: The XTD is a 6-F introducer-compatible device that pulverizes clot with a rotating curved tip driven by a flexible spiral shaft. Fragments are aspirated into a collection container. Fifty patients (32 women; mean age 66 years) with clotted 6-mm polytetrafluoroethylene HDA grafts were treated at 2 medical centers in a study spanning 22 months. In all, 59 procedures were performed on an outpatient basis under monitored conscious sedation. Ancillary techniques were used as needed to treat the underlying cause of the clot. Technical success was defined on a per-procedure basis as removal of sufficient thrombus to visualize the underlying disease without major device-related complications.Results: Technical success was 100%; no device-related adverse events occurred. Immediate clinical success was achieved in 47/59 (80%) cases. Continued clinical success in survivors was 52% (30/58) at 1 month and 46% (26/56) at 3 months. Eliminating from analysis a high-risk patient subgroup (reocclusions, chronically clotted or unsalvageable grafts, untreatable central venous stenosis, and venous anastomoses resistant to wire/ catheter passage) increased the 3-month clinical success to 59% (22/37).Conclusions: The XTD is a promising device capable of safely and effectively declotting PTFE grafts. Further investigation is warranted.
机译:目的:回顾使用新型机械血栓切除术器械去除聚四氟乙烯(PTFE)血液透析通路(HDA)移植物的早期临床经验。方法:XTD是与6-F导引器兼容的器械,可通过由驱动器驱动的旋转弯曲尖端粉碎血块柔性螺旋轴。将碎片吸入收集容器中。在一项为期22个月的研究中,有50个患者(32名女性;平均年龄66岁)患有阻塞性6毫米聚四氟乙烯HDA移植物的治疗。在受监控的清醒镇静下,总共在门诊进行了59次手术。根据需要使用辅助技术来治疗血块的根本原因。技术成功的定义是:按手术的定义是去除足够的血栓以可视化潜在疾病,而没有重大的器械相关并发症。没有发生与设备相关的不良事件。 47/59(80%)病例获得了立即的临床成功。幸存者的持续临床成功率为1个月时为52%(30/58),3个月时为46%(26/56)。从分析中消除了高风险的患者亚组(再阻塞,长期凝结或无法挽救的移植物,无法治愈的中心静脉狭窄以及对金属丝/导管通过有抵抗力的静脉吻合)将3个月的临床成功率提高到59%(22/37)。 :XTD是一种有前途的设备,能够安全有效地去除PTFE接枝。有必要进行进一步调查。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号