Perfect-mixing models are commonly used for analyzing the performance of building ventilation systems. Recently, they have been used to estimate the strength of gas sources in buildings. However, buildings are generally partitioned in such a waythat scalar first-order models are insufficient to completely describe the dynamic behavior of the gas transport in buildings. This paper addresses the question of when scalar, first-order differential equations are useful for describing the aggregatedynamical behavior of multi-variable perfect-mixing processes. Sufficient conditions for the input-output relation of a multi-variable perfect-mixing process to be a first-order differential equation are derived. The conditions are related to sensorlocation and system design. It is shown that the design condition is too restrictive to be widely applicable. Therefore, an alternative first-order relationship is derived by replacing the design condition with a leakage condition. The results enable theestimation of aggregate parameters of multi-zone ventilation systems from scalar, first-order differential equations, which substantially simplifies the estimation problem.
机译:完美混合模型通常用于分析建筑物通风系统的性能。最近,它们已被用于估算建筑物中气源的强度。但是,通常以标量一阶模型不足以完全描述建筑物中气体传输的动态行为的方式对建筑物进行分区。本文讨论了标量一阶微分方程何时可用于描述多变量完美混合过程的集合动力学行为的问题。推导了多变量完美混合过程的输入输出关系成为一阶微分方程的充分条件。条件与传感器位置和系统设计有关。结果表明,设计条件过于严格,无法广泛应用。因此,通过将设计条件替换为泄漏条件,可以得出另一种一阶关系。结果使得能够从标量一阶微分方程估计多区域通风系统的集合参数,从而大大简化了估计问题。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号