In the present study, a simple and sensitive high performance liquid chromatography with fluorescence detection (HPLC-FD) method was developed to determine TJ0711 hydrochloride, a novel alpha- and beta-receptor blocker. TJ0711 hydrochloride and verapamil hydrochloride (the internal standard) were separated on Knauer Eurospher C(18) (250 mm x 4.0 mm i.d., 5 microm) column at 50 degrees C. The mobile phase was methanol:perchloric acid (12 nM, aq) (56:44, v:v), with a flow rate of 1.0 mL/min. The wavelengths of FD were set at 246 nm for excitation and 300 nm for emission. For plasma samples of rats, the analytes were extracted with acetic ether from alkalinized plasma, and then back-extracted into 10 mM dilute sulfuric acid. The linearity was over a concentration range of 20-10,000 ng/mL. The intra- and inter-day precisions referred by relative standard deviation were less than 2.0% and 4.3%, respectively. The mean analytical recoveries of TJ0711 hydrochloride at different concentrations (50, 1000 and 8000 ng/mL) ranged from 88.3% to 92.9%. The lower limit of quantification (LLOQ) was 20 ng/mL. Finally, this method was successfully applied to the estimation of pharmacokinetic parameters of TJ0711 hydrochloride after intravenous doses of 4, 8 and 16 mg/kg in rats.
机译:在本研究中,开发了一种简单而灵敏的高效液相色谱-荧光检测(HPLC-FD)方法来测定TJ0711盐酸盐,一种新型的α和β受体阻滞剂。在Knauer Eurospher C(18)(250 mm x 4.0 mm内径,5微米)色谱柱上于50°C分离TJ0711盐酸盐和维拉帕米盐酸盐(内标)。流动相为甲醇:高氯酸(12 nM,水溶液) (56:44,v:v),流速为1.0 mL / min。 FD的波长设置为246nm用于激发,300nm用于发射。对于大鼠的血浆样品,用乙酸醚从碱化血浆中提取分析物,然后反萃取至10 mM稀硫酸中。线性在20-10,000 ng / mL的浓度范围内。以相对标准偏差表示的日内和日间精度分别小于2.0%和4.3%。在不同浓度(50、1000和8000 ng / mL)下,TJ0711盐酸盐的平均分析回收率在88.3%至92.9%之间。定量下限(LLOQ)为20 ng / mL。最终,该方法成功应用于大鼠静脉内注射4、8和16 mg / kg盐酸TJ0711的药代动力学参数。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号