首页> 外文期刊>Journal of chromatography, B. Analytical technologies in the biomedical and life sciences >Simultaneous electrochemiluminescence determination of sulpiride and tiapride by capillary electrophoresis with cyclodextrin additives
【24h】

Simultaneous electrochemiluminescence determination of sulpiride and tiapride by capillary electrophoresis with cyclodextrin additives

机译:环糊精添加剂的毛细管电泳同时电化学发光法测定舒必利和替普利特

获取原文
获取原文并翻译 | 示例
           

摘要

Sulpiride and tiapride are often used in the treatment of depression, schizophrenia and psychopathology of senescence, gastric or duodenal ulcers and are also partly excreted by kidney. This work developed a simple and sensitive method for their simultaneous monitoring in human urine based on capillary electrophoresis coupled with electrocherniluminescence detection by end-column mode. P-Cyclodextrin (P-CD) was used as an additive to the running buffer to obtain the absolute separation of sulpiride and tiapride. Under optimized conditions the proposed method displayed a linear range from 1.0 x 10(-7) to 1.0 x 10(-4)M for both sulpiride and tiapride with the correlation coefficients more than 0.995 (n = 6). Their limits of detection were 1.0 x 10(-8) M (45 amol) and 1.5 x 10(-8) M (68 amol) at a signal to noise ratio of 3, respectively. The relative standard deviations for six determinations of 2.0 mu M sulpiride and 3.0 mu M tiapride were 1.8 and 2.5%, respectively. For practical application an extract step with ethyl acetate at pH 11 was performed to eliminate the influence of ionic strength in sample. The recoveries of sulpiride and tiapride at different levels in human urine were between 84 and 95%, which showed that the method was valuable in clinical and biochemical laboratories for monitoring sulpiride and tiapride for various purposes. (c) 2006 Elsevier B.V. All rights reserved.
机译:舒必利和替帕必利通常用于治疗抑郁症,精神分裂症和衰老的心理病理学,胃或十二指肠溃疡,也可部分被肾脏排泄。这项工作开发了一种简单而灵敏的方法,用于基于毛细管电泳和通过尾端模式进行电化学发光检测的人类尿液中同时监测。使用P-环糊精(P-CD)作为运行缓冲液的添加剂,以实现舒必利和tiapride的绝对分离。在优化的条件下,所提出的方法对舒必利和替帕利特均表现出从1.0 x 10(-7)到1.0 x 10(-4)M的线性范围,相关系数大于0.995(n = 6)。在信噪比为3时,它们的检出限分别为1.0 x 10(-8)M(45 amol)和1.5 x 10(-8)M(68 amol)。六次测定的2.0μM舒必利和3.0μM的tiapride的相对标准偏差分别为1.8%和2.5%。对于实际应用,执行了用pH为11的乙酸乙酯萃取的步骤,以消除样品中离子强度的影响。在人尿中不同水平的舒必利和替拉必利的回收率在84%到95%之间,这表明该方法在临床和生化实验室中对各种用途的舒必利和替拉必利监测具有重要价值。 (c)2006 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号