首页> 外文期刊>Journal of chromatography, B. Analytical technologies in the biomedical and life sciences >Rapid determination of the synthetic pyrethroid insecticide, deltamethrin, in rat plasma and tissues by HPLC
【24h】

Rapid determination of the synthetic pyrethroid insecticide, deltamethrin, in rat plasma and tissues by HPLC

机译:高效液相色谱法快速测定大鼠血浆和组织中的拟除虫菊酯类杀虫剂溴氰菊酯

获取原文
获取原文并翻译 | 示例
           

摘要

Deltamethrin (DLM), [(S)-alpha-cyano-d-phenoxybenzyl-(1R,3R)-e-(2,2 dibromovinyl)-2,2-dimethylcyclo-propane-1-carboxylate], is a pyrethroid insecticide widely used in agriculture and households. There are several methods for analysis of DLM in biological fluids and tissues, but these methods are time consuming. They generally involve the extraction of DLM with lipid-soluble solvents such as n-pentane, n-hexane, diethylether or acetone, and subsequent evaporation of the solvent. A more rapid and sensitive high-performance liquid chromatography (HIPLC method to analyze DLM in plasma and tissues (liver, kidney, and brain) was developed and validated according to U.S. Food and Drug Administration (U.S. FDA) and International Conference on Harmonization (ICH) of Technical Requirements for Registration of Pharmaceuticals for Human Use guidelines. The limit of detection (S/N of 3/1) for DLM was 0.01 mu g/ml for plasma, liver. kidney and brain. The method performances were shown to be selective for DLM and linear over the concentration range 0.01-20.0 mu g/ml. For five replications of samples at 0.05, 0.1, 0.2, 1.5 and 4.0 mu g/ml, intraday precision and accuracy values were in the range of 0.7-13.1% relative standard deviation (%R.S.D.) and 1.8-14. 1 %Error, respectively. Interday (n = 15) precision and accuracy values at 0.05, 0.1, 0.2, 1.5, and 4.0 mu g/ml were in the range of 3.2-15.2% (%R.S.D.) and 3.7-14.8%Error, respectively. The absolute recoveries of DLM ranged from 93 to 103% for plasma, 95 to 114% for liver. 97 to 108% for kidney, and 95 to 108% for brain. This method can be quite useful for DLM pharmacokinetic and tissue distribution studies, for which multiple plasma and tissue samples have to be analyzed quickly with high reproducibility. (c) 2006 Elsevier B.V. All rights reserved.
机译:溴氰菊酯(DLM),[(S)-α-氰基-d-苯氧基苄基-(1R,3R)-e-(2,2二溴乙烯基)-2,2-二甲基环丙烷-1-羧酸酯]是拟除虫菊酯类杀虫剂广泛用于农业和家庭。有几种分析生物体液和组织中DLM的方法,但是这些方法很耗时。它们通常包括用脂溶性溶剂(例如正戊烷,正己烷,二乙醚或丙酮)萃取DLM,然后蒸发溶剂。根据美国食品药品管理局(US FDA)和国际协调会议(ICH),开发并验证了一种更快速,灵敏的高效液相色谱法(HIPLC方法,用于分析血浆和组织(肝,肾和脑)中的DLM。 ),《用于人类使用的药物注册指南》的技术要求;血浆,肝,肾和脑中DLM的检出限(信噪比为3/1)为0.01μg / ml,结果表明该方法的性能为对DLM具有选择性,并且在0.01-20.0μg / ml的浓度范围内呈线性;对于0.05、0.1、0.2、1.5和4.0μg / ml的五次重复样品,日内精密度和准确度值在0.7-13.1范围内%相对标准偏差(%RSD)和1.8-14。1%误差。日间(n = 15)的精确度和准确度值在0.05、0.1、0.2、1.5和4.0μg / ml的范围内-15.2%(%RSD)和3.7-14.8%Error。DLM的绝对回收率血浆从93%上升到103%,肝脏从95%上升到114%。肾脏为97%至108%,大脑为95%至108%。该方法对于DLM药代动力学和组织分布研究非常有用,因为必须快速分析其多个血浆和组织样品,并具有很高的重现性。 (c)2006 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号