首页> 外文期刊>Journal of chromatography, B. Analytical technologies in the biomedical and life sciences >Simultaneous determination of most prescribed antibiotics in multiple urban wastewater by SPE-LC-MS/MS
【24h】

Simultaneous determination of most prescribed antibiotics in multiple urban wastewater by SPE-LC-MS/MS

机译:SPE-LC-MS / MS同时测定多种城市废水中大多数处方抗生素

获取原文
获取原文并翻译 | 示例
           

摘要

A rapid analytical method was developed for the application of a long-term monitoring (>one year) of the most prescribed and often in hospitals used antibiotics in diverse wastewaters of an urban sewage treatment plant (STP). Additionally to the selected multi-class antibiotics amoxicillin, penicillin V and piperacillin (penicillins), cefotaxime and cefuroxime (cephalosporins), azithromycin, clarithromycin and roxithromycin (macrolids), ciprofloxacin and levofloxacin-ofloxacin (fluoroquinolones), clindamycin (lincosamide), doxycycline (tetracycline), sulfamethoxazole (sulfonamide) and trimethoprim (dihydrofolate reductase inhibitor), the bioactive metabolite clindamycin-sulfoxide, the reserve antibiotic vancomycin (glycopeptide) and as tracer of the STP the anticonvulsant carbamazepine and the antifungal fluconazole were involved. The analytical method combines a low-sample-volume solid phase extraction (SPE), followed by a chromatographic separation using a reversed phase (RP) and hydrophilic interaction liquid chromatography (HILIC) technique, respectively, coupled to a triple quadrupole mass spectrometer. Detection was performed with multiple reaction monitoring (MRM) measured with positive electrospray ionization (ESI+). The extraction efficiency of different SPE cartridges and optimized pH-values of the preparation procedure were tested. Finally, the extraction of antibiotics was realized with the Oasis HLB cartridge and a pH adjustment at 3.5. An external calibration curve in diluted blank urine was used for quality control of the sample set of daily composite samples of the STP for the duration of one year monitoring. The squared coefficient of determination (r~2) in the concentration range (20-20,000 ng/L or 100-100,000 ng/L) of the calibration curves for the method was higher than 0.99 for all determined substances. The limit of quantification (LoQ) ranged between 0.8 ng/L (azithromycin) and 245.1 ng/L (vancomycin). Furthermore, a standard addition was used for quantification in wastewater samples. The process efficiencies ranged from 20% (doxycycline) to 134% (cefuroxime) in influent samples and from 31% (doxycycline) to 171% (cefuroxime) in effluent samples of the STP. All selected substances have been found in wastewater samples. Cefuroxime, doxycycline, levofloxacin, piperacillin, sulfamethoxazole and carbamazepine showed highest concentrations up to 6.2 μg/L.
机译:已开发出一种快速分析方法,用于对处方最频繁且在医院中经常在城市污水处理厂(STP)的各种废水中使用的抗生素进行长期监测(>一年)。除选定的多类抗生素阿莫西林,青霉素V和哌拉西林(青霉素),头孢噻肟和头孢呋辛(头孢菌素),阿奇霉素,克拉霉素和罗红霉素(大环烷烃),环丙沙星和环氧嘧啶环氧嘧​​啶环氧嘧​​啶(氟西汀)四环素),磺胺甲恶唑(磺胺)和甲氧苄啶(二氢叶酸还原酶抑制剂),生物活性代谢物克林霉素亚砜,储备抗生素万古霉素(糖肽)以及作为STP的示踪剂的抗惊厥药卡马西平和抗真菌氟康唑。该分析方法结合了低样品量固相萃取(SPE),然后分别使用反相(RP)和亲水相互作用液相色谱(HILIC)技术进行色谱分离,并与三重四极杆质谱仪联用。使用正电喷雾电离(ESI +)测量的多反应监测(MRM)进行检测。测试了不同SPE柱的提取效率和制备过程的最佳pH值。最终,使用Oasis HLB柱和pH调节至3.5实现了抗生素的提取。将稀释的空白尿液中的外部校准曲线用于STP每日复合样品的样品组的质量控制,持续一年的监测时间。该方法的校准曲线在浓度范围(20-20,000 ng / L或100-100,000 ng / L)中的测定平方系数(r〜2)对于所有测定的物质均高于0.99。定量下限(LoQ)在0.8 ng / L(阿奇霉素)和245.1 ng / L(万古霉素)之间。此外,使用标准添加物对废水样品进行定量。 STP进水样品的处理效率范围为20%(多西环素)至134%(头孢呋辛),而STP废水样品的处理效率为31%(多西环素)至171%(头孢呋辛)。在废水样品中发现了所有选定的物质。头孢呋辛,多西环素,左氧氟沙星,哌拉西林,磺胺甲恶唑和卡马西平的最高浓度最高为6.2μg/ L。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号