首页> 外文期刊>Journal of chromatography, A: Including electrophoresis and other separation methods >Direct determination of free cyanide in drinking water by ion chromatography with pulsed amperometric detection
【24h】

Direct determination of free cyanide in drinking water by ion chromatography with pulsed amperometric detection

机译:脉冲安培检测-离子色谱法直接测定饮用水中的游离氰化物

获取原文
获取原文并翻译 | 示例
           

摘要

Cyanide is a regulated contaminant in drinking water in the United States. This paper describes an ion chromatography method with pulsed amperometric detection (PAD) that directly determines free cyanide in drinking water. Samples are treated with sodium hydroxide to stabilize cyanide and with a cation-exchange cartridge to remove transition metals. Cyanide is separated by anion-exchange chromatography and detected by PAD with a waveform. optimized for cyanide and used with a disposable silver working electrode. The recovery of cyanide spiked into five water samples was > 80%. With an MDL of 1.0 mu g/L, this method determines cyanide concentrations well below the reporting limits for free cyanide in drinking water. (c) 2007 Elsevier B.V. All rights reserved.
机译:在美国,氰化物是饮用水中的受管制污染物。本文介绍了一种采用脉冲安培检测(PAD)的离子色谱方法,该方法可直接测定饮用水中的游离氰化物。样品用氢氧化钠处理以稳定氰化物,并用阳离子交换柱处理以去除过渡金属。氰化物通过阴离子交换色谱分离,并通过PAD波形检测。优化用于氰化物,并与一次性银工作电极一起使用。加标到五个水样中的氰化物的回收率> 80%。当MDL为1.0μg / L时,该方法测定的氰化物浓度远低于饮用水中游离氰化物的报告限值。 (c)2007 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号