We examined the reliability and ease of use of a novel automated transcranial Doppler (TCD) system in comparison to a conventional TCD system. TCD ultrasound allows non-invasive monitoring of cerebral blood flow, and can predict arterial vasospasm after a subarachnoid hemorrhage (SAH). The Presto 1000 TCD system (PhysioSonics, Bellevue, WA, USA) is designed for monitoring flow through the M1 segment of the middle cerebral artery (MCA) via temporal windows. The Presto 1000 system was tested across multiple preclinical and clinical settings in parallel with a control predicate TCD system. In a phantom flow generating device, both the Presto 1000 and Spencer system (Spencer Technologies, Redmond, WA, USA) were able to detect velocities with high accuracy. In nine volunteer patients, the Presto system was able to locate the MCA in 14 out of 18 temporal windows, in an average of 12.5 s. In the SAH cohort of five patients with a total of 25 paired measurements, the mean absolute difference in flow velocities of the M1 segment, as measured by the two systems, was 17.5 cm/s. These data suggest that the Presto system offers an automated TCD that can reliably localize and detect flow of the MCA, with relative ease of use. The system carries the additional benefit of requiring minimal training for the operator, and can be used by many providers across multiple bedside settings. The mean velocities that were generated warrant further validation across an extended group of patients, and the predictive value for vasospasm should be checked against the current standard of angiography. (C) 2015 Elsevier Ltd. All rights reserved.
机译:我们检查了与传统的TCD系统相比,新型自动经颅多普勒(TCD)系统的可靠性和易用性。 TCD超声可以无创地监测脑血流,并可以预测蛛网膜下腔出血(SAH)后的动脉血管痉挛。 Presto 1000 TCD系统(PhysioSonics,Bellevue,WA,USA)设计用于通过时间窗监视通过大脑中动脉(MCA)的M1段的血流。 Presto 1000系统在多种临床前和临床环境中与对照谓词TCD系统并行测试。在幻影流生成设备中,Presto 1000和Spencer系统(Spencer Technologies,美国华盛顿州雷德蒙德)均能够高精度检测速度。在9名志愿者患者中,Presto系统能够在18个颞窗中的14个中定位MCA,平均时间为12.5 s。在共有25个配对测量值的五名患者的SAH队列中,由两个系统测量的M1段流速的平均绝对差为17.5 cm / s。这些数据表明,Presto系统提供了一个自动化的TCD,它可以相对容易地使用,能够可靠地定位和检测MCA的流量。该系统还具有对操作员进行最少培训的额外好处,并且可以由许多提供者在多个床头环境中使用。产生的平均速度值得在扩展的患者组中进一步验证,并且应根据当前的血管造影标准检查血管痉挛的预测值。 (C)2015 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号