A novel superstructure-based MINLP formulation is proposed for the synthesis of cooling water networks with intermediate mains.The proposed mathematical model considers the generic problem confronted in the design of a recirculating cooling-water system,including stretching the cooler network design and setting the operation constraints.Besides the original design items,this research probes into how the number of intermediate cooling-water mains influences the performance of a recirculating cooling-water system.We also study how the conditional direct connections between cooling units can decrease the consumption of the recirculating cooling-water with a little sacrifice of pipeline complexity.Typical representative examples are presented to demonstrate the viability of proposed superstructure-based MINLP formulation.Supported by the results of computer analysis,the network superstructure and its design scheme can effectively accomplish the goal of unraveling the design problem of the recirculating cooling-water system with intermediate cooling-water mains,and proffering the optimal structure in designing the recirculating cooling-water systems.
机译:提出了一种基于上层结构的新型MINLP公式,用于合成带有中间电源的冷却水网络。该数学模型考虑了循环冷却水系统设计中遇到的一般问题,包括扩展冷却器网络设计和设置运行方式除了最初的设计项目外,本研究还探讨了中间冷却水总管数量如何影响循环冷却水系统的性能。我们还研究了冷却单元之间的有条件直接连接如何减少循环水的消耗给出了典型的实例来说明所提出的基于上层建筑的MINLP配方的可行性。在计算机分析结果的支持下,网络上层建筑及其设计方案可以有效地实现拆解目标的设计问题具有中间冷却水总管的循环冷却水系统,并在设计循环冷却水系统时提供了最佳结构。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号