The AOAC Germicidal Spray Products as Disinfectants test method (AOAC Official Method 961.02) is used to measure the efficacy of spray products on hard inanimate surfaces; however, the method does not provide procedures to determine the population ofthe test microbe on inoculated glass slide carriers (e.g., carrier counts reported as CFU/carrier). Without a method to measure and monitor carrier counts, the associated efficacy data may not be reliable and repeatable. This report provides a standardized procedure to address this issue and, based on carrier count data collected by four laboratories from 2000 to 2010, proposes a specific range for the mean log density per carrier as a requirement. Laboratory-based carrier count data were collected concurrently with 116 Method 961.02 efficacy tests conducted on spray products bearing claims against Pseudomonas aeruginosa and Staphylococcus aureus. For many of the tests a soil load (SL) was added to the inoculum (as specified on the product label claim). Six carriers were assayed per test for a total of 696 carriers. All but two of the 116 mean log densities were at least 5.0 (a geometric mean of 1.0x105 CFU/carrier). Across the four combinations of microbes and SL treatments, the mean TestLD (mean logdensity across all enumerated carriers in a test) ranged from approximately 6.0 (a geometric mean of 0.9 x 10~6 CFU/carrier) to 6.3 (a geometric mean of 2.0 x10~6 CFU/carrier). Across all microbes and SL treatments, the mean log density (±SEM) was 6.2(+0.07) per carrier (a geometric mean of 1.5x10~6 CFU/carrier). The mean log density for six carriers per test showed good repeatability (0.32) and reproducibility (0.34). The proposed requirement for S. aureus tests and P. aeruginosa tests is a mean logdensity (across six carriers) between 5.0 and 6.5. A separate 2009 study at three laboratories was conducted to evaluate the persistence of P. aeruginosa, S. aureus, and Salmonella enterica on glass carriers. Based on the persistence data, a 2 h use period is proposed for using the inoculated carriers post drying. The persistence data set was also used to assess the carrier counts for S. enterica. The carrier counts were approximately one log lower for S. enterica compared to S. aureus and P. aeruginosa; a range of 4.0 to 5.5 logs is proposed as a requirement for S. enterica tests.
机译:AOAC杀菌剂杀虫喷雾产品测试方法(AOAC官方方法961.02)用于测量喷雾产品在硬无生命表面上的功效;但是,该方法没有提供确定接种的载玻片载体上测试微生物种群的程序(例如,以CFU /载体报告的载体计数)。如果没有一种测量和监视携带者数量的方法,则相关的功效数据可能不可靠且不可重复。本报告提供了解决此问题的标准化程序,并根据四个实验室从2000年到2010年收集的载剂计数数据,提出了一个要求,即每个载具的平均对数密度的特定范围。在对带有铜绿假单胞菌和金黄色葡萄球菌要求保护的喷雾产品上进行的116方法961.02功效测试的同时,收集了基于实验室的载体计数数据。对于许多测试,将土壤负荷(SL)添加到接种物中(按照产品标签上的说明)。每个测试分析了六个载体,总共696个载体。在116个平均对数密度中,除两个以外的所有密度均至少为5.0(几何平均数为1.0x105 CFU /载体)。在微生物和SL处理的四种组合中,平均TestLD(测试中所有枚举载体的平均对数密度)范围从大约6.0(几何平均值为0.9 x 10〜6 CFU /载体)到6.3(几何平均值为2.0) x10〜6 CFU /载波)。在所有微生物和SL处理中,每个载体的平均对数密度(±SEM)为6.2(+0.07)(几何平均值为1.5x10〜6 CFU /载体)。每个测试六个载流子的平均对数密度显示出良好的重复性(0.32)和重现性(0.34)。金黄色葡萄球菌测试和铜绿假单胞菌测试的拟议要求是平均对数密度(横跨六个载体)在5.0到6.5之间。 2009年在三个实验室进行的另一项研究评估了铜绿假单胞菌,金黄色葡萄球菌和肠沙门氏菌在玻璃载体上的持久性。根据持久性数据,建议在干燥后2小时内使用接种的载体。持久性数据集还用于评估肠炎链球菌的携带者计数。与金黄色葡萄球菌和铜绿假单胞菌相比,小肠链球菌的携带者数量大约低了一个对数。提出了4.0到5.5个原木的范围作为肠炎沙门氏菌检测的要求。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号