The State of Washington has found that the Spokane River is DO impaired, and is requiring dischargers to reduce phosphorus inputs to the river. Spokane County elected to build a new water recovery facility with a target effluent total phosphorus level of 50 mu g/L on a seasonal average basis. Spokane County elected to use a private company to design/build and operate their facility. The very low nutrient requirements, and lack of historical operating information, necessitated an integrated approach to the nutrient removal design while considering the risks and benefits of the various treatment options. The process selection evaluated membrane bioreactors and tertiary membranes for the primary liquids process in combination with chemical and/or biological phosphorus removal. The final process selection included chemically enhanced primary treatment, membrane bioreactor with metal salts, and dewatering liquor treatment with an innovative post aerobic digestion step.
机译:华盛顿州发现斯波坎河的溶解氧受到损害,并要求排放者减少向该河的磷输入。斯波坎县选择建造一座新的水回收设施,其目标废水总磷水平按季节平均为50克/升。斯波坎县选择使用一家私人公司来设计/建造和运营其设施。对养分的要求非常低,并且缺乏历史操作信息,因此在考虑各种处理方案的风险和收益的同时,必须采用一种综合的方法进行养分去除设计。工艺选择评估了膜生化反应器和第三级膜的原液工艺,并结合了化学和/或生物除磷技术。最终工艺选择包括化学增强的一级处理,带有金属盐的膜生物反应器以及带有创新的后需氧消化步骤的脱水液处理。