A submersible UV/VIS spectrometer was used to monitor a paper mill wastewater treatment plant. It utilises the UV/VIS range (200-750 nm) for simultaneous measurement of COD, filtered COD, TSS and nitrate with just a single instrument. The instrument measures in-situ, directly in the process. Paper mill wastewater shows typical and reproducible spectra at various process measuring points. There is a relative maximum at 280 mm due to the absorbance by dissolved organic substances, mainly ligninic acids. Comparison of absorbance spectra distinctly shows the decrease of this peak, indicating biological degradation throughout the treatment process. Summarising, one can say that paper mill wastewater cannot be monitored by a simple UV probe measuring only the absorbance at a single wavelength. The required information can only be gained from the whole spectra. Regarding plant control it is suggested that only the overall spectral information is used. Calibrations to conventional parameters are now merely carried out for purposes of reference-checking. [References: 5]
机译:潜水式UV / VIS光谱仪用于监测造纸厂废水处理厂。它利用UV / VIS范围(200-750 nm)只需一台仪器即可同时测量COD,过滤的COD,TSS和硝酸盐。仪器直接在过程中进行现场测量。造纸厂废水在各个过程测量点均显示出典型且可重现的光谱。由于被溶解的有机物质(主要是木质素酸)的吸收,在280毫米处有一个相对最大值。吸收光谱的比较清楚地表明该峰的减少,表明在整个处理过程中生物降解。总而言之,可以说造纸厂废水不能通过仅测量单个波长下的吸光度的简单紫外线探针进行监测。只能从整个光谱中获得所需的信息。关于工厂控制,建议仅使用总光谱信息。现在仅出于参考检查的目的对常规参数进行校准。 [参考:5]

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号