摘要

To establish a new method for the diagnosis of dengue secondary infection, 187 serum samples from the patients with dengue secondary infection, 40 serum samples from the patients with dengue primary infection, and 44 serum samples from the healthy volunteers were tested using the dengue IgG indirect enzyme-linked immunosorbent assay (DEN IgG ELISA). The results of the test were compared with those from the dengue hemagglutination inhibition (DEN HI) test, which has been recommended as the gold standard by the World Health Organization (WHO, 1997). Japanese encephalitis IgG indirect ELISA (JE IgG ELISA) was also performed to measure anti-flavivirus IgG, which cross-reacts with the Japanese encephalitis virus, to test the possibility of an alternative to DEN IgG ELISA. The results of DEN IgG and JE IgG ELISAs were highly correlated with those of the DEN HI test. In the DEN IgG ELISA, a titer of 1:29,000 was the cut-off value for the diagnosis of dengue secondary infection (91.5% accuracy [95% confidence interval, CI], 90.9% sensitivity [95%CI], and 92.9% specificity [95%CI]). A titer of 1:52,000 was the cut-off value for dengue secondary infection using JE IgG ELISA (95.6% accuracy [95%CI], 98.9% sensitivity [95%CI], and 88.1% specificity [95%CI]). In conclusion, this study confirmed that the results of both DEN IgG and JE IgG ELISAs were highly correlated with the results of DEN HI test. Thus, these ELISAs are simple, rapid, sensitive, and quantitative tests that can be used in the determination of dengue secondary infection.
机译:为了建立诊断登革热继发感染的新方法,使用登革热IgG间接检测了187例登革热继发感染患者的血清样本,40例登革热原发感染患者的血清样本和44例健康志愿者的血清样本酶联免疫吸附测定(DEN IgG ELISA)。将测试结果与登革热血凝抑制测试(DEN HI)进行了比较,该测试已被世界卫生组织推荐为金标准(WHO,1997)。还进行了日本脑炎IgG间接ELISA(JE IgG ELISA)来测量与日本脑炎病毒交叉反应的抗黄病毒IgG,以测试替代DEN IgG ELISA的可能性。 DEN IgG和JE IgG ELISA的结果与DEN HI测试的结果高度相关。在DEN IgG ELISA中,滴度为1:29,000是诊断登革热继发感染的临界值(准确度为91.5%[95%置信区间,CI],90.9%敏感性[95%CI]和92.9%特异性[95%CI]。使用JE IgG ELISA的登革热继发感染的临界值为1:52,000(准确度为95.6%[95%CI],灵敏度为98.9%[95%CI]和88.1%特异性为[95%CI])。总之,这项研究证实了DEN IgG和JE IgG ELISAs的结果都与DEN HI测试的结果高度相关。因此,这些ELISA是简单,快速,灵敏和定量的测试,可用于确定登革热继发感染。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号