Background: The time from sampling to analysis can be delayed when blood samples are shipped to distant reference laboratories or when analysis cannot be readily performed. Objective: The objective of this study was to evaluate the stability of hematologic analytes in blood samples from monkeys, rabbits, rats, and mice when samples were stored for up to 72 hours at 4 degrees C. Methods: Blood samples from 30 monkeys, 15 rabbits, 20 rats, and 30 mice were collected into EDTA-containing tubes and were initially analyzed within 1 hour of collection using the ADVIA 120 analyzer. The samples were then stored at 4 degrees C and reanalyzed at 24, 48, and 72 hours after collection. Results: Significant (P<.0003) changes in hematologic analytes and calculations included increased HCT and MCV and decreased MCHC and cell hemoglobin concentration mean (CHCM) at 72 hours and increased MPV at 24 hours in monkeys; increased MCV at 72 hours and MPV at 48 hours and decreased monocyte count at 24 hours in rabbits; increased MCV and decreased MCHC, CHCM, and monocyte count at 24 hours in rats; increased MCV, red cell distribution width, and MPV and decreased MCHC, CHCM, and monocyte count at 24 hours in mice. Conclusions: Although most of the changes in the hematologic analytes in blood from monkeys, rabbits, rats, and mice when samples were stored at 4 degrees C were analytically acceptable and clinically negligible, the best practice in measuring hematologic analytes in these animals is timely processing of blood samples, preferably within 1 hour after collection.
机译:背景:当血液样本被运送到遥远的参考实验室或无法轻易进行分析时,从采样到分析的时间可能会延迟。目的:本研究的目的是评估在4摄氏度下将猴子,兔子,大鼠和小鼠的血液样本中血液分析物的稳定性,其保存时间长达72小时。方法:30只猴子,15只猴子的血液样本将兔,20只大鼠和30只小鼠收集到含EDTA的试管中,并在收集后的1小时内使用ADVIA 120分析仪进行初步分析。然后将样品存储在4摄氏度下,并在收集后的24、48和72小时重新分析。结果:血液分析物中的显着变化( P <。0003),计算结果包括:猴子在72小时时HCT和MCV升高,MCHC和细胞血红蛋白浓度平均值(CHCM)降低,而在24小时时MPV升高;兔72小时MCV增加,MPV 48小时增加,MPV减少24小时;大鼠24小时MCV升高,MCHC,CHCM和单核细胞计数降低;小鼠在24小时时MCV,红细胞分布宽度和MPV升高,MCHC,CHCM和单核细胞计数降低。结论:尽管在4摄氏度下保存样品时,猴子,兔子,大鼠和小鼠血液中血液学分析物的大多数变化在分析上是可接受的,在临床上可以忽略不计,但在这些动物中测量血液学分析物的最佳实践是及时处理血液样本,最好在收集后1小时内。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号