Two different confocalmicro X-ray fluorescence spectrometers have been developed and installed atOsaka City University and the Vienna University of Technology Atominstitut. The Osaka City University systemis a high resolution spectrometer operating in air. The Vienna University of Technology Atominstitut spectrometer has a lower spatial resolution but is optimized for light element detection and operates under vacuum condition. The performance of both spectrometers was compared. In order to characterize the spatial resolution, a set of nine specially prepared single element thin film reference samples (500nmin thickness, Al, Ti, Cr, Fe Ni, Cu, Zr, Mo, and Au) was used. Lower limits of detection were determined using the National Institute of Standards and Technology standard referencematerial glass standard 1412. A paint layer sample (cultural heritage application) and paint on automotive steel samples were analyzed with both instruments. The depth profile information was acquired by scanning the sample perpendicular to the surface.
机译:大阪市立大学和维也纳工业大学已经开发并安装了两种不同的共聚焦X射线荧光光谱仪。大阪市立大学系统是在空​​气中运行的高分辨率光谱仪。维也纳科技大学原子光谱仪具有较低的空间分辨率,但针对轻元素检测进行了优化,并在真空条件下运行。比较了两种光谱仪的性能。为了表征空间分辨率,使用了一组九个专门准备的单元素薄膜参考样品(厚度为500nmin,Al,Ti,Cr,Fe Ni,Cu,Zr,Mo和Au)。使用美国国家标准技术研究所标准参考材料玻璃标准1412确定检测下限。使用这两种仪器分析了油漆层样品(文化遗产应用)和汽车钢样品上的油漆。深度剖面信息是通过垂直于表面扫描样品而获得的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号