...
首页> 外文期刊>Translational stroke research >Acute Multi-modal Neuroimaging in a Porcine Model of Endothelin-1-Induced Cerebral Ischemia: Defining the Acute Infarct Core
【24h】

Acute Multi-modal Neuroimaging in a Porcine Model of Endothelin-1-Induced Cerebral Ischemia: Defining the Acute Infarct Core

机译:内皮素-1诱发的脑缺血的猪模型中的急性多模式神经影像:定义急性梗死核心。

获取原文
获取原文并翻译 | 示例
           

摘要

In a porcine ischemic stroke model, we sought to compare the acute predicted infarct core volume (PIV) defined by CT perfusion (CTP)-hemodynamic parameters and MR-diffusion-weighted imaging (MR-DWI)/apparent diffusion coefficient (ADC), with the true infarct core volume (TIV) as defined by histology. Ten Duroc-cross pigs had a CTP scan prior to injection of endothelin-1 (ET-1) into the left striatum. CTP scans were used to monitor ischemic progression. A second dose of ET-1 was injected 2 h from the first injection. The animal was moved to a 3-T MRI scanner where DWI was performed. CTP imaging was acquired immediately after the MR imaging. Next, the brain was removed and stained with tetrazolium chloride (TTC). Linear regression and Bland-Altman plots were used to correlate the PIV measured by each imaging modality to that of the TIV from the histological gold standard. The CTP-cerebral blood flow (CBF) parameter had the highest R (2) value and slope closest to unity, while the CTP-cerebral blood volume (CBV) had the lowest R (2) value and slope furthest away from unity. The CTP-CBFaEuro cent CBV product parameter had a higher R (2) value but lower slope than both MR parameters. The best Bland-Altman agreement was observed with the CTP-CBF parameter. PIV from MR-DWI, ADC, and CTP-CBF overestimated the TIV defined with histology. We show that the PIV defined with absolute gray and white matter CT-CBF thresholds correlates best with the TIV and is similar to both MR-DWI and ADC-defined PIVs. Further, the acute CBFaEuro cent CBV mismatch may not indicate penumbral tissue in the acute stroke setting.
机译:在猪缺血性中风模型中,我们试图比较由CT灌注(CTP)-血流动力学参数和MR弥散加权成像(MR-DWI)/表观弥散系数(ADC)定义的急性预测梗死核心体积(PIV),组织学所定义的真实梗死核心体积(TIV)。在将内皮素1(ET-1)注入左纹状体之前,对十只Duroc杂交猪进行了CTP扫描。 CTP扫描用于监测缺血进程。从第一次注射开始2小时注射第二次ET-1。将动物移至进行DWI的3-T MRI扫描仪中。 MR成像后立即获取CTP成像。接下来,移出大脑,并用氯化四唑(TTC)染色。使用线性回归和Bland-Altman图将每种成像方式测得的PIV与组织学金标准的TIV进行关联。 CTP脑血流量(CBF)参数具有最高的R(2)值和最接近单位的斜率,而CTP脑血容量(CBV)具有最低的R(2)值和最远离单位的斜率。 CTP-CBFaEuro cent CBV产品参数的R(2)值较高,但斜率低于两个MR参数。使用CTP-CBF参数观察到最佳的Bland-Altman协议。来自MR-DWI,ADC和CTP-CBF的PIV高估了组织学定义的TIV。我们显示,用绝对灰和白质CT-CBF阈值定义的PIV与TIV最佳相关,并且与MR-DWI和ADC定义的PIV相似。此外,急性CBFaEurocent CBV不匹配可能并不表示急性中风时半影组织。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号