首页> 外文期刊>The Journal of Physiology >Selective recruitment of single motor units in human flexor digitorum superficialis muscle during flexion of individual fingers.
【24h】

Selective recruitment of single motor units in human flexor digitorum superficialis muscle during flexion of individual fingers.

机译:在单个手指屈曲过程中,选择性地招募人浅指浅肌中单个运动单元。

获取原文
获取原文并翻译 | 示例
           

摘要

Flexor digitorum superficialis (FDS) is an extrinsic multi-tendoned muscle which flexes the proximal interphalangeal joints of the four fingers. It comprises four digital components, each with a tendon that inserts onto its corresponding finger. To determine the degree to which these digital components can be selectively recruited by volition, we recorded the activity of a single motor unit in one component via an intramuscular electrode while the subject isometrically flexed each of the remaining fingers, one at a time. The finger on which the unit principally acted was defined as the 'test finger' and that which flexed isometrically was the 'active' finger. Activity in 79 units was recorded. Isometric finger flexion forces of 50% maximum voluntary contraction (MVC) activated less than 50% of single units in components of FDS acting on fingers that were not voluntarily flexed. With two exceptions, the median recruitment threshold for all active-test finger combinations involving the index, middle, ring and little finger test units was between 49 and 60% MVC (60% MVC being the value assigned to those not recruited). The exceptions were flexion of the little finger while recording from ring finger units (median: 40% MVC), and vice versa (median: 2% MVC). For all active-test finger combinations, only 35/181 units were activated when the active finger flexed at less than 20% MVC, and the fingers were adjacent for 28 of these. Functionally, to recruit FDS units during grasping and lifting, relatively heavy objects were required, although systematic variation occurred with the width of the object. In conclusion, FDS components can be selectively activated by volition and this may be especially important for grasping at high forces with one or more fingers.
机译:指浅屈肌(FDS)是一种外在的多肌腱肌肉,可弯曲四个手指的近指指间关节。它包含四个数字组件,每个组件都有一根插入其相应手指上的肌腱。为了确定通过意志选择性地募集这些数字组件的程度,我们通过肌内电极记录了一个组件中单个运动单元的活动,而受试者等轴测地一次弯曲了其余每个手指。该单元主要作用的手指被定义为“测试手指”,等轴测弯曲的手指被定义为“活动”手指。记录了79个单位的活性。 50%最大自愿收缩(MVC)的等距手指屈曲力激活的FDS组件中作用于未自愿屈曲的手指的单个单元的激活率不到50%。除了两个例外,所有涉及食指,中指,无名指和小指测试单位的主动测试手指组合的中值征募门槛为49至60%MVC(60%MVC为分配给未征募者的价值)。从无名指单位录制时小指弯曲(中位数:MVC为40%),反之亦然(中位数:2%MVC)。对于所有主动测试手指组合,当主动手指以小于20%的MVC弯曲时,只有35/181个单位被激活,并且其中28个手指相邻。在功能上,要在抓握和提起期间招募FDS单位,需要相对较重的物体,尽管物体的宽度会发生系统性变化。总而言之,FDS组件可以通过意志选择性地激活,这对于用一个或多个手指以较高的力抓握尤其重要。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com