PURPOSE: Vessel sealing capabilities and the peripheral energy spread associated with currently available energy based surgical instruments were evaluated. MATERIALS AND METHODS: Four groups of energy based surgical instruments were established for evaluation, including the ACE, LCS-C5 (Ethicon, Cincinnati, Ohio), LigaSure V and the prototype Trissector. In vivo vessel diameter under physiological conditions, bursting pressures and seal failure were recorded and analyzed for arteries and veins separately. After burst testing the vessels were fixed and evaluated histopathologically for peripheral energy damage. ANOVA was used to determine differences between groups. RESULTS: The LigaSure V sealed arteries and veins with an average burst pressure of 536 and 386 mm Hg, respectively. The Harmonic ACE sealed arteries and veins with an average burst pressure of 436 and 160 mm Hg, respectively. The Harmonic LCS-C5 sealed arteries and veins with an average burst pressure of 363 and 215 mm Hg, respectively. TheTrissector sealed arteries and veins with an average burst pressure of 328 and 237 mm Hg, respectively. For arteries the ACE, LCS-C5, Trissector and LigaSure V measured a full-thickness peripheral energy spread of 0.6, 0.3, 8.0 and 4.5 mm, respectively (p <0.0001). For veins the ACE, LCS-C5, Trissector and LigaSure V measured a full-thickness peripheral energy spread of 1.5, 1.3, 8.5 and 6.3 mm, respectively (p = 0.003). CONCLUSIONS: The LigaSure 5 was superior to the other devices tested regarding the ability to seal vessels up to 7 mm. The ACE is an efficient vessel sealing system with the ability to seal vessels up to 5 mm.
机译:目的:评估与当前可用的基于能量的手术器械相关的血管密封能力和周围能量散布。材料与方法:建立了四组基于能量的手术器械进行评估,包括ACE,LCS-C5(Ethicon,辛辛那提,俄亥俄州),LigaSure V和原型Trissector。记录生理条件下的体内血管直径,破裂压力和密封失败,并分别分析动脉和静脉。爆破测试后,将血管固定并通过组织病理学评估周围能量是否受损。方差分析用于确定组之间的差异。结果:LigaSure V密封的动脉和静脉的平均破裂压力分别为536和386 mm Hg。 Harmonic ACE密封的动脉和静脉的平均破裂压力分别为436和160 mm Hg。 Harmonic LCS-C5密封的动脉和静脉的平均破裂压力分别为363和215 mm Hg。 Trissector密封的动脉和静脉的平均破裂压力分别为328和237 mm Hg。对于动脉,ACE,LCS-C5,Trissector和LigaSure V测量的全厚度周围能量散布分别为0.6、0.3、8.0和4.5毫米(p <0.0001)。对于静脉,ACE,LCS-C5,Trissector和LigaSure V测量的全厚度周围能量散布分别为1.5、1.3、8.5和6.3毫米(p = 0.003)。结论:LigaSure 5在密封最大7毫米血管的能力方面优于其他测试的设备。 ACE是一种高效的容器密封系统,能够密封最大5毫米的容器。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号