Repeatability and interdevice reliability of two portable color selection devices in matching and measuring tooth color.

机译:两个便携式选色设备在匹配和测量牙齿颜色时的可重复性和设备间可靠性。

获取原文
获取原文并翻译 | 示例
           

摘要

STATEMENT OF PROBLEM: There is a need to know how shade selection devices perform in matching and measuring tooth color, since these functions are usually evaluated independently and may present significant discrepancies. PURPOSE: The purpose of this study was to evaluate 2 devices which offer both functions to test the null hypothesis that they present no differences in their repeatability and interdevice reliability relating to the 2 functions. MATERIAL AND METHODS: Thirty-one extracted anterior human teeth were measured twice, with each of the devices (ShadeEye NCC and VITA EasyShade), by one investigator experienced and calibrated with both devices. L*a*b* values and shade matches to VITA Classical and Vitapan 3D-Master shade guide systems were determined for all teeth. Paired t tests and intraclass correlation coefficients (ICCs) were used to statistically analyze the data (alpha=.05). RESULTS: The results showed that L*a*b* values with VITA EasyShade were significantly higher than those with ShadeEye NCC (P<.01), with a mean difference of 10.01 Delta E units. Device repeatability ICCs for measuring tooth color ranged from 0.693 to 0.929, with significant differences between devices only with respect to parameter L* (P=.042). Intradevice ICCs for matching tooth color ranged from 0.714 to 0.894, with significant differences between devices only with respect to the VITA Classical shade system (P=.042). Interdevice ICCs for measuring tooth color ranged from 0.402 to 0.486, with no significant differences between L*a*b* parameters, while interdevice matching reliability ranged from 0.189 to 0.430, with no significant differences between shade systems (P>.05). CONCLUSIONS: All tooth color parameters were higher with the VITA EasyShade device. Measuring repeatability of the VITA EasyShade was higher than the ShadeEye NCC only for the L* parameter. Matching repeatability of the ShadeEye NCC was higher than the VITA EasyShade for the VITA Classical system. Interdevice measuring reliabilities were not different for the color parameters, but matching reliability of the VITA Classical system was higher than that of the Vitapan 3D-Master.
机译:问题陈述:有必要知道遮光罩选择装置在匹配和测量牙齿颜色方面的表现,因为这些功能通常是独立评估的,并且可能存在重大差异。目的:本研究的目的是评估2个提供两种功能的设备,以检验零假设,即它们在重复性和与2个功能相关的设备间可靠性方面没有差异。材料和方法:一位研究人员对这两种设备(ShadeEye NCC和VITA EasyShade)进行了两次测量,并对31种拔出的人类前牙进行了两次测量。确定了所有牙齿的L * a * b *值以及与VITA Classical和Vitapan 3D-Master阴影引导系统的阴影匹配度。配对的t检验和类内相关系数(ICC)用于统计分析数据(alpha = .05)。结果:结果显示,VITA EasyShade的L * a * b *值显着高于ShadeEye NCC的L * a * b *值(P <.01),平均差为10.01 Delta E单位。用于测量牙齿颜色的设备可重复性ICC在0.693至0.929的范围内,仅在参数L *上设备之间存在显着差异(P = .042)。与牙齿颜色匹配的设备内ICC在0.714到0.894之间,仅在VITA Classical遮阳系统方面,设备之间的ICC差异显着(P = .042)。用于测量牙齿颜色的设备间ICC在0.402至0.486之间,L * a * b *参数之间无显着差异,而设备间匹配可靠性在0.189至0.430之间,在遮阳系统之间无显着差异(P> .05)。结论:VITA EasyShade设备的所有牙齿颜色参数均较高。仅对于L *参数,VITA EasyShade的测量重复性高于ShadeEye NCC。 ShadeEye NCC的匹配重复性高于VITA Classical系统的VITA EasyShade。设备间的测量可靠性在颜色参数上没有差异,但是VITA Classical系统的匹配可靠性高于Vitapan 3D-Master。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号