首页> 外文期刊>The journal of knee surgery >Validation of a novel smartphone accelerometer-based knee goniometer.
【24h】

Validation of a novel smartphone accelerometer-based knee goniometer.

机译:基于新型智能手机加速计的膝关节测角仪的验证。

获取原文
获取原文并翻译 | 示例
       

摘要

Loss of full knee extension following anterior cruciate ligament surgery has been shown to impair knee function. However, there can be significant difficulties in accurately and reproducibly measuring a fixed flexion of the knee. We studied the interobserver and the intraobserver reliabilities of a novel, smartphone accelerometer-based, knee goniometer and compared it with a long-armed conventional goniometer for the assessment of fixed flexion knee deformity. Five healthy male volunteers (age range 30 to 40 years) were studied. Measurements of knee flexion angle were made with a telescopic-armed goniometer (Lafayette Instrument, Lafayette, IN) and compared with measurements using the smartphone (iPhone 3GS, Apple Inc., Cupertino, CA) knee goniometer using a novel trigonometric technique based on tibial inclination. Bland-Altman analysis of validity and reliability including statistical analysis of correlation by Pearson's method was undertaken. The iPhone goniometer had an interobserver correlation (r) of 0.994 compared with 0.952 for the Lafayette. The intraobserver correlation was r = 0.982 for the iPhone (compared with 0.927). The datasets from the two instruments correlate closely (r = 0.947) are proportional and have mean difference of only -0.4 degrees (SD 3.86 degrees). The Lafayette goniometer had an intraobserver reliability +/- 9.6 degrees. The interobserver reliability was +/- 8.4 degrees. By comparison the iPhone had an interobserver reliability +/- 2.7 degrees and an intraobserver reliability +/- 4.6 degrees. We found the iPhone goniometer to be a reliable tool for the measurement of subtle knee flexion in the clinic setting.
机译:前交叉韧带手术后失去全膝关节伸展已被证实会损害膝关节功能。然而,在准确和可重复地测量膝盖的固定屈曲方面可能存在很大的困难。我们研究了一种新型的,基于智能手机加速度计的膝关节测角仪的观察者间和观察者内可靠性,并将其与长臂常规测角仪进行了比较,以评估固定屈曲性膝关节畸形。研究了五名健康的男性志愿者(年龄在30至40岁之间)。使用伸缩臂式测角仪(Lafayette Instrument,Lafayette,IN)进行膝部弯曲角度的测量,并与智能手机(iPhone 3GS,Apple Inc.,Cupertino,CA)使用基于三角胫骨的新型三角技术,将其与膝部测角仪进行比较。倾角。进行了有效性和可靠性的Bland-Altman分析,包括采用Pearson方法的相关性统计分析。 iPhone测角仪的观察者间相关性(r)为0.994,而拉斐特人为0.952。 iPhone的观察者内相关系数为r = 0.982(相比之下,为0.927)。来自这两个工具的数据集紧密相关(r = 0.947),它们是成比例的,并且平均差仅为-0.4度(SD 3.86度)。拉斐特测角仪的观察者内部可靠性为+/- 9.6度。观察者之间的可靠性为+/- 8.4度。相比之下,iPhone的观察者之间的可靠性为+/- 2.7度,观察者内部的可靠性为+/- 4.6度。我们发现iPhone测角仪是在临床环境中测量细微膝盖弯曲的可靠工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号