We undertook a simulated-use study using quantitative methods to evaluate the cleaning efficacy of ported and non-ported accessory devices used in minimally invasive surgery. We chose laparoscopic scissors and forceps to represent worst-case devices which were inoculated with artificial test soil containing 10(6)cfu/mL Enterococcus faecalis and Geobacillus stearothermophilus and allowed to dry for 1 h. Cleaning was performed manually, as well as by the automated SI-Auto Narrow lumen cleaner. Manual cleaning left two- to 50-fold more soil residuals (protein, haemoglobin and carbohydrate) inside the lumen of non-ported versus ported laparoscopic accessory devices. The SI-Auto Narrow lumen cleaner was more efficient than manual cleaning and achieved >99% reduction in soil parameters in both non-ported (using retro-flushing) and ported laparoscopic devices. Only the automated cleaning of ported devices achieved 10(3)-10(4)-fold reduction in bacterial numbers. Sonication alone (no flushing of inner channel)did not effectively remove soil or organisms from the inner channel. Our findings indicate that non-ported accessory devices cannot be as reliably cleaned as ported devices regardless of the cleaning method used. If non-ported accessory devices are reprocessed, they should be cleaned using retro-flushing in an automated narrow lumen cleaner.
机译:我们使用定量方法进行了模拟使用研究,以评估微创手术中使用的便携式和非便携式配件的清洁效果。我们选择了腹腔镜剪刀和镊子来代表最坏情况的设备,这些设备已接种了含有10(6)cfu / mL粪肠球菌和嗜热脂肪地芽孢杆菌的人工试验土壤,并干燥1小时。手动或通过自动SI-Auto Narrow流明清洁器进行清洁。手动清洁与非便携式腹腔镜附属设备相比,非便携式腔内残留的土壤残留量(蛋白质,血红蛋白和碳水化合物)增加了2到50倍。 SI-Auto窄腔清洁器比手动清洁更有效,并且在非便携式(使用反冲洗)和便携式腹腔镜设备中,土壤参数降低了99%以上。只有对携带式设备的自动清洁才能使细菌数量减少10(3)-10(4)倍。单独的超声处理(不冲洗内部通道)并不能有效去除内部通道中的土壤或生物。我们的发现表明,无论使用哪种清洁方法,非便携式附件设备都无法像便携式设备那样可靠地清洁。如果对非端口附件设备进行了重新处理,则应使用自动窄腔清洁器中的反冲洗功能对其进行清洁。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号