首页> 外文期刊>The Journal of Allergy and Clinical Immunology >Do subjects investigated for occupational asthma through serial peak expiratory flow measurements falsify their results?
【24h】

Do subjects investigated for occupational asthma through serial peak expiratory flow measurements falsify their results?

机译:通过连续性呼气峰值流量测量对职业性哮喘进行调查的受试者是否伪造了其结果?

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND AND AIM: Serial assessment of peak expiratory flow (PEF) rates has been advocated as a sensitive and specific means of investigating occupational asthma. The possibility that, for several reasons, subjects do not accurately report their values has been raised. The availability of portable instruments that assess PEF and store timings and values now make it possible to estimate compliance and accuracy of results. METHODS: Twenty-one subjects consecutively investigated for occupational asthma were asked to assess their PEF every 2 hours during the day, both at work and away from work, with a VMX instrument (Clement Clarke International, Columbus, Ohio) and record the times and values on a sheet of paper. The subjects were not aware that the data were also being stored on a computer chip. The diagnosis was occupational asthma in eight subjects, personal asthma in four subjects, and neither condition in nine subjects. RESULTS: The mean duration of recording was 36 days (range, 14 to 79 days). Atleast 6048 values should have been recorded, but only 4839 (80%) were either recorded or stored. Reported values corresponded precisely to stored values in 2533 of 4839 recordings (52%). The timing of the recording was also examined in relation to the time at which the recording was solicited; values recorded within 1 hour of the solicited time were judged as acceptable. Of the total of 3342 recordings stored, 2375 (71%) satisfied this criterion. Compliance was significantly less satisfactory in those referred by the Workers' Compensation Board (n = 11). CONCLUSION: In this survey of 21 subjects investigated for possible occupational asthma, compliance with PEF recording, as assessed by comparing recorded and stored results and the time at which the recording was solicited, was poor.
机译:背景与目的:提倡对呼气峰值流量(PEF)进行连续评估是研究职业性哮喘的敏感而具体的方法。由于多种原因,受试者没有准确报告其价值观的可能性已经提出。评估PEF并存储时间和值的便携式仪器的可用性现在使估算合规性和结果准确性成为可能。方法:要求连续调查了21名职业性哮喘的受试者在一天中和下班时每两小时使用VMX仪器(俄亥俄州哥伦布市的克莱门特·克拉克国际组织)评估其PEF,并记录时间和一张纸上的值。受试者不知道数据也被存储在计算机芯片上。诊断为八名受试者为职业性哮喘,四名受试者为个人哮喘,九名受试者均未发现病情。结果:平均录音时间为36天(范围为14到79天)。应该已经记录了Atleast 6048的值,但是仅记录或存储了4839(80%)。报告的值与4839个记录中的2533个存储的值精确对应(52%)。还检查了记录的时间与请求记录的时间有关。在请求的时间1小时内记录的值被认为是可接受的。在总共存储的3342个记录中,有2375个(71%)满足此条件。工人补偿委员会推荐的合规性明显较差(n = 11)。结论:在本次调查的21名可能患有职业性哮喘的受试者中,通过比较记录和存储的结果以及请求记录的时间来评估对PEF记录的依从性较差。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号