BACKGROUND & OBJECTIVES: Improper practices of making direct smears of sputum for detection of acid-fast bacilli (AFB) and of disposing sputum cups are hazardous. The present study was undertaken with the objective to stain sputum samples in their containers by 'phenol (10%) ammonium sulphate (4%) basic fuchsin (2%) solution' and to decolourize and counterstain their smears for detection of AFB- (henceforth called pot method) and to compare the smear results of pot method with the standard Ziehl-Neelsen (ZN) method. METHODS: A total of 575 selected sputum samples from pulmonary tuberculosis patients were stained by the standard ZN and pot methods and the proportions of AFB positive smears were compared. RESULTS: Of the 575 samples, 126 were AFB positive for both the staining methods and the difference was not statistically significant. Pot method missed 9 ZN positive smears (8 scanty and one 1+) and ZN method missed 9 pot positive smears (9 scanty) and the difference was not significant. High grade smears (3+) were seen more in pot method (42) than in ZN method (25) and the difference was significant. INTERPRETATION & CONCLUSION: Our findings showed that pot method was comparable to standard ZN method and had many advantages. Pot method can be explored further for the detection of AFB in sputum samples obtained from pulmonary tuberculosis suspects.
机译:背景与目的:不正确的做法是对痰液进行直接涂片检查以检测耐酸杆菌(AFB),并丢弃痰杯。进行本研究的目的是用'苯酚(10%)硫酸铵(4%)碱性品红(2%)溶液'对容器中的痰液样本进行染色,并对它们的涂片进行脱色和复染色以检测AFB-(此后(称为锅法),并将锅法的涂片结果与标准的Ziehl-Neelsen(ZN)方法进行比较。方法:采用标准的ZN和盆法对从肺结核患者中抽取的575份痰标本进行染色,比较AFB阳性涂片的比例。结果:在575个样本中,两种染色方法中的126个均为AFB阳性,且差异无统计学意义。锅法漏检了9个ZN阳性涂片(8个稀少和1个1+),而ZN法漏了检漏9个ZN阳性涂片(9个稀少),差异不显着。在盆栽法(42)中比在ZN方法(25)中观察到更高等级的涂片(3+),差异显着。解释与结论:我们的发现表明,锅法可与标准ZN法相媲美,并具有许多优势。锅法可以进一步探索检测从肺结核嫌疑人获得的痰样品中的AFB。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号