...
首页> 外文期刊>The Analyst: The Analytical Journal of the Royal Society of Chemistry: A Monthly International Publication Dealing with All Branches of Analytical Chemistry >Determination of residues of the plant growth regulator chlormequat in pears by ion-exchange high performance liquid chromatography-electrospray mass spectrometry
【24h】

Determination of residues of the plant growth regulator chlormequat in pears by ion-exchange high performance liquid chromatography-electrospray mass spectrometry

机译:离子交换高效液相色谱-电喷雾质谱法测定梨中植物生长调节剂百草枯的残留量

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

We report a method which we have used routinely for the determination of chlormequat residues in pears. After extraction with methanal, determination was performed, without clean-up, by ion-exchange HPLC using an SCX column eluted with aqueous ammonium formate-methanol, and HPLC-MS with an electrospray interface. MS and MS-MS were employed concurrently, using selected ion monitoring and selected reaction monitoring, respectively, of the Cl-35 and Cl-37 isotopes of the chlormequat cation and the CID transitions of each of these precursors to the common product ion at mit 58. The method was suitable for determinations at concentrations of chlormequat cation of 0.04 mg kg(-1). Concentrations determined using the four signals were in goad agreement (mean RSD 3%). The mean recovery of chlormequat cation at 0.16 mg kg(-1), measured using the mit 122-->,58 signal, was 86% (RSD 7%) under repeatability conditions and 88% (RSD 15%) in routine application of the method over a 3 month period. Analysis of an in-house reference sample of pears, similarly analysed over the 3 month period, gave an RSD of 10% with a mean of 0.14 mg kg(-1). Mean recovery at 0.016 mg kg-l,under repeatability conditions on two occasions, was 101% (RSD 6%) and 56% (RSD 12%). [References: 23]
机译:我们报告了一种我们常规用于测定梨中氯麦草残留量的方法。用甲烷甲烷萃取后,无需离子交换色谱法即可进行测定,无需纯化,方法是使用用甲酸铵-甲醇水溶液洗脱的SCX色谱柱和具有电喷雾接口的HPLC-MS。同时使用MS和MS-MS,分别使用氯甲基阳离子的Cl-35和Cl-37同位素进行选定的离子监测和选定的反应监测,并在mit时将这些前体中的每一个前体的CID转变为共同产物离子58.该方法适用于测定0.04 mg kg(-1)的氯甲基阳离子浓度。使用这四个信号确定的浓度符合目标浓度(平均RSD为3%)。使用mit 122->,58信号测得的0.16 mg kg(-1)的四氯甲烷阳离子的平均回收率在重复性条件下为86%(RSD 7%),在常规应用中为88%(RSD 15%)。该方法需要3个月的时间。在3个月的时间内对梨的内部参考样品进行的分析相似,得出RSD为10%,平均值为0.14 mg kg(-1)。在两次重复性条件下,以0.016 mg kg-1的平均回收率分别为101%(RSD 6%)和56%(RSD 12%)。 [参考:23]

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号