首页> 外文期刊>Talanta: The International Journal of Pure and Applied Analytical Chemistry >Simultaneous determination of lead and cadmium in various environmental and biological samples by differential pulse polarography after adsorption of their morpholine-4-carbodithioates onto microcrystalline naphthalene or morpholine-4-dithiocarbamate
【24h】

Simultaneous determination of lead and cadmium in various environmental and biological samples by differential pulse polarography after adsorption of their morpholine-4-carbodithioates onto microcrystalline naphthalene or morpholine-4-dithiocarbamate

机译:在微晶萘或吗啉-4-二硫代氨基甲酸酯上吸附吗啉-4-碳二硫代吗啉后,通过差分脉冲极谱法同时测定各种环境和生物样品中的铅和镉。

获取原文
获取原文并翻译 | 示例
           

摘要

A highly selective, sensitive and rapid differential pulse polarographic method (DPP) has been developed for the simultaneous estimation of trace amounts of lead and cadmium in standard alloys, biological and environmental samples. The morpholine-4-carbodithioates of the samples were absorbed on microcrystalline naphthalene in the pH range of 5–10 for lead and 3.4–11 for cadmium. The metal complexes were desorbed with 10 ml of 1M HCl and determined simultaneously with a differential pulse polarograph. These metals can alternatively be quantitatively adsorbed on morpholine-4-dithiocarbamate-cetyltrimethylammonium bromide-naphthalene adsorbent packed in a column and determined similarly. The detection limits are 0.14 ppm for Pb and 0.014 ppm for Cd at minimum instrumental settings (signal-to-noise ratio = 2). The linearity is maintained in the concentration ranges of Pb, 0.7–15 ppm and Cd, 0.07–10 ppm with a correlation factor of 0.9997 and relative standard deviations of 0.95 and 0.81%, respectively. Various parameters such as the effect of pH, volume of aqueous phase, and interference of a number of metal ions on the estimation of lead and cadmium have been studied in detail to optimize the conditions for their simultaneous estimation in various biological and environmental samples.
机译:已开发出一种高度选择性,灵敏且快速的差分脉冲极谱法(DPP),用于同时估算标准合金,生物和环境样品中的痕量铅和镉。样品的吗啉-4-碳二硫代酸盐在铅的5-10和镉的3.4-11的pH范围内被微晶萘吸收。金属络合物用10 ml 1M HCl解吸,并同时用差分脉冲极谱仪测定。另外,这些金属可以定量地吸附在装在柱中的吗啉-4-二硫代氨基甲酸酯-鲸蜡基三甲基溴化萘-萘吸附剂上,并进行类似测定。在最小仪器设置下(信噪比= 2),铅的检出限为0.14 ppm,镉的检出限为0.014 ppm。在Pb,0.7-15 ppm和Cd,0.07-10 ppm的浓度范围内保持线性关系,相关系数为0.9997,相对标准偏差分别为0.95和0.81%。已详细研究了各种参数,例如pH,水相体积和多种金属离子的干扰对铅和镉估算的影响,以优化在各种生物和环境样品中同时估算铅和镉的条件。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号