首页> 外文期刊>Peritoneal dialysis international: Journal of the International Society for Peritoneal Dialysis >An exploratory study of a novel peritoneal combination dialysate (1.36% glucose/7.5% icodextrin), demonstrating improved ultrafiltration compared to either component studied alone.
【24h】

An exploratory study of a novel peritoneal combination dialysate (1.36% glucose/7.5% icodextrin), demonstrating improved ultrafiltration compared to either component studied alone.

机译:一种新型腹膜联合透析液(1.36%葡萄糖/7.5%二十二碳精蛋白)的探索性研究,与单独研究的任何一种成分相比,其超滤性能均得到改善。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVE: Concerns regarding the impact of ultrafiltration failure on peritoneal dialysis and the effect of hypertonic glucose on the peritoneal membrane have lead to a search for alternative dialysates. Computer simulations based on the three-pore theory suggest that a combination of 1.36% glucose and 7.5% icodextrin (glucose polymer) offers an improved ultrafiltration profile. The aim of the present study was to investigate the ultrafiltration profile of this combination fluid. DESIGN: Prospective open study comparing 1.36% glucose, 3.86% glucose, 7.5% icodextrin, and the combination fluid (1.36% glucose/7.5% icodextrin). SETTING: Sheffield Kidney Institute, Northern General Hospital, Sheffield, UK. PATIENTS: 11 patients currently using peritoneal dialysis not previously exposed to icodextrin. MAIN OUTCOME MEASURE: Intraperitoneal volume was measured using a radioisotope dilution method. RESULTS: The combination fluid showed a biphasic ultrafiltration profile, with a steep initial increase in intraperitoneal volume, then a maintained plateau phase for the duration of the study dwell (7 hours). The final volume was greater than that with the 1.36% glucose dwell and the 7.5% icodextrin dwell. The fluid was well tolerated by the patients. CONCLUSIONS: These findings are in keeping with computer simulations using the three-pore model. The combination fluid offers an improved ultrafiltration profile, with a final volume similar to 3.86% glucose, while avoiding exposing the peritoneal membrane to high glucose concentrations. It may have a role as a long dwell to optimize ultrafiltration and possibly prolong peritoneal dialysis technique survival.
机译:目的:有关超滤失败对腹膜透析的影响以及高渗葡萄糖对腹膜的影响的担忧导致人们寻求替代的透析液。基于三孔理论的计算机模拟表明,1.36%葡萄糖和7.5%icodextrin(葡萄糖聚合物)的组合可提供改善的超滤特性。本研究的目的是研究这种混合液的超滤特性。设计:一项前瞻性开放研究,比较了1.36%葡萄糖,3.86%葡萄糖,7.5%的艾考糊精和混合液(1.36%的葡萄糖/7.5%的艾考糊精)。地点:英国谢菲尔德北部总医院谢菲尔德肾脏研究所。患者:11名目前正在接受腹膜透析的患者以前未接受过艾考糊精治疗。主要观察指标:腹腔体积采用放射性同位素稀释法测量。结果:混合液表现出双相超滤特征,腹膜内体积最初急剧增加,然后在研究停留期间(7小时)保持稳定的高原期。最终体积大于具有1.36%葡萄糖滞留和7.5%艾考糊精滞留的体积。患者对液体的耐受性良好。结论:这些发现与使用三孔模型的计算机模拟是一致的。混合液提供了改进的超滤特性,最终体积类似于3.86%的葡萄糖,同时避免将腹膜暴露于高浓度的葡萄糖中。它可能起长时滞作用,以优化超滤效果并可能延长腹膜透析技术的生存期。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号