首页> 外文期刊>Urology >Reliability of color Doppler ultrasound urodynamics in the evaluation of bladder outlet obstruction.
【24h】

Reliability of color Doppler ultrasound urodynamics in the evaluation of bladder outlet obstruction.

机译:彩色多普勒超声尿流动力学评估膀胱出口梗阻的可靠性。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVES: To analyze the intrarater and interrater reliability of a newly developed noninvasive urodynamic technique based on color Doppler ultrasound for the evaluation of bladder outlet obstruction. We previously demonstrated the feasibility of this new technique. METHODS: Color Doppler ultrasound urodynamic evaluations were performed on 31 men with and without bladder outlet obstruction. An ultrasound image-directed Doppler system with a 3.75-MHz probe operated by a remote control robotic manipulator was used to obtain color scale data using the transperineal approach in men during voiding. We measured the flow velocities in the distal prostatic (V1) and membranous urethra (V2) and used them to obtain the velocity ratio (VR = V1/V2). Combining this information with simultaneous uroflowmetry, the functional cross-sectional area of the distal prostatic urethra (A1) was calculated. These parameters were independently reinterpreted by an inexperienced investigator using the color image data stored in a personal computer. The intrarater and interrater reliability for VR were assessed using a classification based on cutoff values previously shown to indicate the presence or absence of obstruction. RESULTS: The retest correlation using Spearman's rho for VR in terms of intrarater and interrater reliability was 0.95 and 0.57, respectively; that for A1 was 0.97 and 0.64, respectively. Using a VR of less than 1.1 (to indicate the absence of obstruction) and a VR greater than 1.6 (to indicate the presence of obstruction) for classification, intrarater and interrater agreement occurred in 93.6% to 96.8% and 77.4% to 83. 9% of cases, respectively. CONCLUSIONS: The color Doppler ultrasound urodynamic technique for noninvasive evaluation of bladder outlet obstruction can be performed with reasonable reliability.
机译:目的:分析一种新开发的基于彩色多普勒超声的无创尿流动力学技术,用于评估膀胱出口梗阻的评分者和间位者可靠性。我们之前已经证明了这项新技术的可行性。方法:对31例有或没有膀胱出口梗阻的男性进行了彩色多普勒超声尿流动力学评估。在排尿过程中,使用经会阴方法对男性进行超声图像定向的多普勒系统,该系统具有由遥控机器人操纵器操作的3.75 MHz探针,以获取色标数据。我们测量了远端前列腺(V1)和膜状尿道(V2)的流速,并用它们来获得流速比(VR = V1 / V2)。将该信息与同时尿流法相结合,可计算出远端前列腺尿道(A1)的功能截面积。没有经验的研究人员使用存储在个人计算机中的彩色图像数据独立地重新解释了这些参数。使用基于先前显示的指示存在或不存在阻塞的临界值的分类,对VR的评估者内和间间可靠性进行评估。结果:使用Spearman的rho进行VR复测的相关性分别为0.95和0.57。 A1的分别为0.97和0.64。使用小于1.1的VR(表示没有障碍)和大于1.6的VR(表示存在障碍)进行分类,评分者和分居者达成的同意率分别为93.6%至96.8%和77.4%至83. 9分别为%的案件。结论:彩色多普勒超声尿流动力学技术可无创地评估膀胱出口梗阻的可靠性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号