首页> 外文期刊>Thermal engineering >Results from Comprehensive Thermal and Chemical Tests of Steam Generator No. 2 in Unit 1 at the Volgodonsk Nuclear Power Station
【24h】

Results from Comprehensive Thermal and Chemical Tests of Steam Generator No. 2 in Unit 1 at the Volgodonsk Nuclear Power Station

机译:伏尔加东斯克核电站1号机组2号蒸汽发生器的综合热化学测试结果

获取原文
获取原文并翻译 | 示例
           

摘要

We present the results from investigating the distribution of the concentrations of sodium and iron (Ⅱ + Ⅲ) in the water volume of a steam generator and an analysis of their behavior in the course of blowdown operations carried out in accordance with the existing maintenance procedure when the power unit is run with its reactor plant operating at a power of 100% N_(nom) under the conditions of an all-volatile water chemistry.
机译:我们提供了根据蒸汽发生器的水量中钠和铁(Ⅱ+Ⅲ)的浓度分布进行调查的结果,并根据现有维护程序对排污操作过程中它们的行为进行了分析。在全挥发性水化学条件下,动力装置的反应堆装置应以100%N_(nom)的功率运行。