首页> 外文期刊>Research journal of applied science, engineering and technology >The Optimization Test Study for the Vacuum System of Piping Main-Scheme in the 600MW Unit
【24h】

The Optimization Test Study for the Vacuum System of Piping Main-Scheme in the 600MW Unit

机译:600MW机组管道主系统真空系统的优化试验研究

获取原文
获取原文并翻译 | 示例
           

摘要

The operation mode of dual-pressure condenser directly influences the vacuum, which makes the entire enthalpy change to affect the economy of the unit. In the vacuum system for the dual-pressure condenser, it is different for the vacuum influenced by both the piping-main scheme and the individual running, which gets along with the load. When the load is higher, the piping-main scheme running is suggested. Contrarily, the individual running is done. Compared to the piping-main scheme running, it can make the higher side pressure reduce 0.12 kPa, which is an obvious effect. The method provides the operation references for energy-saving of the plant.
机译:双压冷凝器的运行方式直接影响真空度,使整个焓变影响机组的经济性。在双压冷凝器的真空系统中,真空受管道主方案和单独运行(随负载而变化)的影响而有所不同。当负载较高时,建议运行主管道方案。相反,个人跑步已经完成。与配管主方案运行相比,可使较高的侧压力降低0.12 kPa,效果显着。该方法为工厂节能提供了操作参考。