首页> 外文期刊>Radiation Protection Dosimetry >SUBOPTIMAL MODULATION OF RADIATION DOSE IN THE COMPUTED TOMOGRAPHY COMPONENT OF WHOLE-BODY POSITRON EMISSION TOMOGRAPHY/COMPUTED TOMOGRAPHY
【24h】

SUBOPTIMAL MODULATION OF RADIATION DOSE IN THE COMPUTED TOMOGRAPHY COMPONENT OF WHOLE-BODY POSITRON EMISSION TOMOGRAPHY/COMPUTED TOMOGRAPHY

机译:全身正电子发射断层扫描/计算机断层扫描计算断层扫描组件中辐射剂量的次优

获取原文
获取原文并翻译 | 示例
           

摘要

Radiation exposure in computed tomography (CT) is automatically modulated by automatic exposure control (AEC) mainly based on scout images. To simulate the whole-body positron emission tomography/CT, CT images of a phantom were obtained using the posteroanterior scout image alone (PA scout) or the posteroanterior and lateral images (PA + Lat scout). Old and new versions of the AEC software were compared. Using the old version of the software and the PA scout, a markedly high dose at the top of the head was observed, which varied depending on the position of the phantom. This issue was resolved in the new version of the software. Radiation dose in the shoulder region was much higher using the PA scout than using the PA + Lat scout, even with the new version of the software. AEC may cause unreasonably high radiation exposure locally, and the appropriateness of the dose modulation pattern should be examined at each facility.
机译:计算机断层扫描(CT)中的辐射曝光是通过自动曝光控制(AEC)自动调制的,主要基于Scout图像。为了模拟全身正电子发射断层摄影术/ CT,使用单独的后剖视图(PA SCOUT)或后剖视图(PA + LAT SCOUT)获得幽灵的CT图像。比较了AEC软件的旧版本。使用旧版本的软件和PA Scout,观察到头部顶部的显着高剂量,这取决于幻象的位置。此问题已在新版本的软件中得到解决。肩部区域中的辐射剂量使用PA Scout比使用PA + LAT Scout的辐射剂量要高得多,即使是新版本的软件。 AEC可能在本地引起不合理的高辐射曝光,并且应在每个设施中检查剂量调制模式的适当性。

著录项

  • 来源
    《Radiation Protection Dosimetry》 |2020年第1期|69-74|共6页
  • 作者单位

    Department of Diagnostic Radiology Kitasato University School of Medicine 1-15-1 Kitasato Minami-ku Sagamihara Kanagawa Japan;

    Department of Diagnostic Radiology Kitasato University School of Medicine 1-15-1 Kitasato Minami-ku Sagamihara Kanagawa Japan;

    Department of Diagnostic Radiology Kitasato University School of Medicine 1-15-1 Kitasato Minami-ku Sagamihara Kanagawa Japan;

    Department of Radiology Kitasato University Hospital 1-15-1 Kitasato Minami-ku Sagamihara Kanagawa Japan;

    Department of Radiology Kitasato University Hospital 1-15-1 Kitasato Minami-ku Sagamihara Kanagawa Japan;

    Department of Radiology Kitasato University Hospital 1-15-1 Kitasato Minami-ku Sagamihara Kanagawa Japan;

    Department of Radiology Kitasato University Hospital 1-15-1 Kitasato Minami-ku Sagamihara Kanagawa Japan;

  • 收录信息 美国《科学引文索引》(SCI);美国《化学文摘》(CA);