The authors describe a method for calculating margins to voltage instability. The method is based on sensitivity techniques. The measure of voltage instability can be given in terms of MW, MVAr or MVA depending on the components in the increase in load. The extensions to earlier publications of the method are the ability to increase the load and generation simultaneously on several buses without increasing the computation time. A single forward and backward substitution is sufficient to find the required sensitivities when the load is increased. The production of the plant can be increased either by a specified profile or by using the turbine droop characteristics. A method for identification of contingencies needing an explicit reserve evaluation is briefly described.
机译:作者介绍了一种计算电压不稳定性裕量的方法。该方法基于灵敏度技术。电压不稳定性的量度可以用MW,MVAr或MVA表示,具体取决于负载增加中的组件。该方法的早期出版物的扩展是能够在不增加计算时间的情况下同时增加多条总线上的负载和发电量。当负载增加时,单个向前和向后替换就足以找到所需的灵敏度。可以通过指定的配置文件或通过使用涡轮机下垂特性来增加设备的产量。简要描述了一种用于识别需要明确准备金评估的或有事项的方法。