A method for simultaneously measuring 6DOF geometric motion errors of a precision rotary stage based on absolute position-distance measurement

机译:一种用于基于绝对位置距离测量的精密旋转级的6dof几何运动误差的方法

获取原文
获取原文并翻译 | 示例
           

摘要

In this paper, an absolute position-distance measurement based method for simultaneous measurement of six-degree-of-freedom (6DOF) errors of a precision rotary stage is proposed. This method uses the multi-wavelength phase-shifting interferometry technology and high-speed CCD camera to measure the instantaneous absolute spatial posture of the specially designed micro structure feature following the movement of a measured rotary stage. By analyzing the spatial posture of a series of instantaneous micro structure features, the 6DOF errors of the precision rotary stage are separated. The simultaneous, high precision and dynamically continuous measurement of 6DOF errors of the precision rotary stage is achieved. To improve the accuracy of error analysis, a model of 6DOF errors of the precision rotary stage is established to determine the mapping relationship between the 6DOF errors and the spatial posture of the micro structure feature. A test platform for 6DOF geometric motion errors of the precision rotary stage is built. The measurement results demonstrate the effectiveness and accuracy of the proposed method.
机译:在本文中,提出了一种基于绝对的位置 - 距离测量用于同时测量精密旋转级的六自由度(6dof)误差的方法。该方法使用多波长相移干涉机技术和高速CCD摄像机来测量测量旋转级移动后的特殊设计的微结构特征的瞬时绝对空间姿势。通过分析一系列瞬时微结构特征的空间姿势,精密旋转级的6dof误差是分开的。实现了精密旋转级6dof误差的同时,高精度和动态连续测量。为了提高误差分析的准确性,建立了精度旋转级的6dof误差模型,以确定6dof误差与微结构特征的空间姿势之间的映射关系。构建了精密旋转级的6DOF几何运动误差的测试平台。测量结果证明了所提出的方法的有效性和准确性。

著录项

  • 来源
    《Optics and Lasers in Engineering》 |2021年第3期|106420.1-106420.12|共12页
  • 作者单位

    Huazhong Univ Sci & Technol Sch Mech Sci & Engn Dept Instrument Sci & Technol State Key Lab Digital Mfg Equipment & Technol Wuhan 430074 Peoples R China;

    Huazhong Univ Sci & Technol Sch Mech Sci & Engn Dept Instrument Sci & Technol State Key Lab Digital Mfg Equipment & Technol Wuhan 430074 Peoples R China;

    Huazhong Univ Sci & Technol Sch Mech Sci & Engn Dept Instrument Sci & Technol State Key Lab Digital Mfg Equipment & Technol Wuhan 430074 Peoples R China;

    Huazhong Univ Sci & Technol Sch Mech Sci & Engn Dept Instrument Sci & Technol State Key Lab Digital Mfg Equipment & Technol Wuhan 430074 Peoples R China;

    Huazhong Univ Sci & Technol Sch Mech Sci & Engn Dept Instrument Sci & Technol State Key Lab Digital Mfg Equipment & Technol Wuhan 430074 Peoples R China;

    Huazhong Univ Sci & Technol Sch Mech Sci & Engn Dept Instrument Sci & Technol State Key Lab Digital Mfg Equipment & Technol Wuhan 430074 Peoples R China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    6DOF errors; Precision rotary stage; Simultaneous measurement; Absolute position-distance measurement; Micro structure feature;