首页> 外文期刊>Journal of Constructional Steel Research >Experimental investigation of slitted web steel moment resisting frame
【24h】

Experimental investigation of slitted web steel moment resisting frame

机译:纵梁腹板抗弯框架的试验研究

获取原文
获取原文并翻译 | 示例
       

摘要

This paper presents the results of three tests to evaluate cyclic behavior of Special Moment Resisting Frames (SMRF) with Slitted web section (SW-MRF). Typically, in SMRFs energy is dissipated by formation of plastic hinges at the beam ends. Nevertheless, based on the recent seismic codes, the span-to-depth ratio of beams in SMRFs should be larger than a minimum value to assure the development of plastic hinges with sufficient length at beam ends, reducing application of short span beams. In this paper, a new approach is proposed for short and medium span beams to transmit the flexural plastic hinges from the beam ends to the beam center by slitting a portion of the beam web at the mid-span and formation of a shear link. The idea can be applied for design of new buildings and for the purpose of rehabilitation in the damaged SMRFs. Two single-bay one-story SW-MRFs are constructed and tested under the quasi-static cyclic loading. One test was conducted on a new frame and the other test on an already flexurally damaged frame. This paper describes the specimen design, construction, experimental setup and results of the test. The test results are compared with the corresponding MRF specimen with a similar geometry and material properties. The results indicate that the proposed idea provides a stiff and ductile system via stable hysteretic loops, which makes it a suitable option for the design of new buildings and retrofit of damaged moment resisting frames. (C) 2018 Elsevier Ltd. All rights reserved.
机译:本文介绍了三种测试的结果,这些测试用于评估带有抗剪腹板截面(SW-MRF)的特殊抗弯框架(SMRF)的循环行为。通常,在SMRF中,通过在梁端形成塑料铰链来耗散能量。但是,根据最近的地震法规,SMRF中的梁跨度与深度之比应大于最小值,以确保开发出在梁端具有足够长度的塑料铰链,从而减少短跨度梁的应用。在本文中,提出了一种新的方法,通过在中跨切开梁腹板的一部分并形成剪力连接,将中短跨度的梁将挠性塑料铰链从梁端传递到梁中心。该想法可用于新建筑的设计以及受损SMRF中的修复目的。在准静态循环载荷下构造并测试了两个单层一层SW-MRF。一项测试是在新框架上进行的,另一项测试是在已经弯曲损坏的框架上进行的。本文介绍了标本的设计,构造,实验设置和测试结果。将测试结果与具有相似几何形状和材料特性的相应MRF样品进行比较。结果表明,所提出的想法通过稳定的磁滞回线提供了刚性和延性的系统,这使其成为设计新建筑物和改造抗破坏框架的合适选择。 (C)2018 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号