首页> 外文期刊>The International Journal of Cardiovascular Imaging >Reproducibility of Shin’s method for necrotic core and calcium content in atherosclerotic coronary lesions treated with bioresorbable everolimus-eluting vascular scaffolds using volumetric intravascular ultrasound radiofrequency-based analysis
【24h】

Reproducibility of Shin’s method for necrotic core and calcium content in atherosclerotic coronary lesions treated with bioresorbable everolimus-eluting vascular scaffolds using volumetric intravascular ultrasound radiofrequency-based analysis

机译:基于容积式血管内超声射频分析的生物可吸收依维莫司洗脱血管支架治疗Shin方法在动脉粥样硬化性冠状动脉病变中坏死核心和钙含量的重现性

获取原文
获取原文并翻译 | 示例
           

摘要

Although Virtual Histology intravascular ultrasound (VH-IVUS) is increasingly used in clinical research, the reproducibility of plaque composition remains unexplored in significant coronary artery and stented lesions. The purpose of this study was to assess the reproducibility of necrotic core and calcium content in atherosclerotic coronary lesions that were treated with a bioresorbable everolimus-eluting vascular scaffold (BVS) using a new measurement method (Shin’s method) by VH-IVUS. Eight patients treated with a BVS (Abbott Vascular, Santa Clara, CA, USA) were analyzed with serial VH-IVUS assessments, i.e., pre- and post-stenting, and at 6 months and 2 years follow-up. A total of 32 coronary segments were imaged to evaluate the reproducibility of volumetric VH-IVUS measurements. In Shin’s method, contours are drawn around the IVUS catheter (instead of the lumen) and vessel. Overall, in the imaged coronary segment, for necrotic core and dense calcium volumes, the relative intra-observer differences were 0.30 ± 0.22, 0.19 ± 0.16% for observer 1 and 0.45 ± 0.41, 0.36 ± 0.47% for observer 2, respectively. The inter-observer relative differences of necrotic core and dense calcium volumes were 0.51 ± 0.79 and 0.56 ± 1.01%, respectively. The present study demonstrates a good reproducibility for both, intra-observer and inter-observer measurements using Shin’s method. This method is suitable for the measurement of necrotic core and dense calcium using VH-IVUS in longitudinal studies, especially studies on bioresorbable scaffolds, because the degradation process will be fully captured independently of the location of the struts and their greyscale appearance.
机译:尽管虚拟组织学血管内超声(VH-IVUS)在临床研究中越来越多地使用,但斑块成分的可重复性在重要的冠状动脉和支架病变中仍未得到研究。这项研究的目的是评估VH-IVUS采用一种新的测量方法(Shin法),使用可生物吸收的依维莫司洗脱血管支架(BVS)治疗的动脉粥样硬化性冠状动脉病变中坏死核心和钙含量的可重复性。对8例接受BVS治疗的患者(美国加利福尼亚州圣克拉拉市的Abbott Vascular公司)进行了连续VH-IVUS评估,即在支架置入前后,以及术后6个月和2年进行了分析。总共对32个冠状动脉段进行了成像,以评估VH-IVUS体积测量值的可重复性。用Shin的方法,在IVUS导管(而不是管腔)和血管周围绘制轮廓。总体而言,在成像的冠状动脉节段中,对于坏死核心和密集的钙量,观察者1的相对观察者内部差异为0.30±0.22,观察者2的相对观察者差异分别为0.45±0.41,0.36±0.47%。坏死核心和密集钙体积的观察者间相对差异分别为0.51±0.79和0.56±1.01%。本研究表明使用Shin方法在观察者内部和观察者之间进行测量均具有良好的可重复性。这种方法适用于在纵向研究中,尤其是对生物可吸收支架的研究中,使用VH-IVUS测量坏死核和致密钙,因为降解过程将被完全捕获,而与支杆的位置及其灰度外观无关。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号