首页> 外文期刊>Infection Control and Hospital Epidemiology >Implementation of an Industrial Systems-Engineering Approach to Reduce the Incidence of Methicillin-Resistant Staphylococcus aureus Infection
【24h】

Implementation of an Industrial Systems-Engineering Approach to Reduce the Incidence of Methicillin-Resistant Staphylococcus aureus Infection

机译:实施工业系统工程方法以减少耐甲氧西林金黄色葡萄球菌感染的发生

获取原文
获取原文并翻译 | 示例
           

摘要

Objective. To measure the effectiveness of an industrial systems-engineering approach to a methicillin-resistant Staphylococcus aureus (MRSA) prevention program.nnDesign. Before-after intervention studynnSetting. An intensive care unit (ICU) and a surgical unit that was not an ICU in the Pittsburgh Veterans Administration hospitalnnPatients. All patients admitted to the study unitsnnIntervention. We implemented an MRSA infection control program that consisted of the following 4 elements: (1) the use of standard precautions for all patient contact, with emphasis on hand hygiene; (2) the use of contact precautions for interactions with patients known to be infected or colonized with MRSA; (3) the use of active surveillance cultures to identify patients who were asymptomatically colonized with MRSA; and (4) use of an industrial systems-engineering approach, the Toyota Production System, to facilitate consistent and reliable adherence to the infection control program.nnResults. The rate of healthcare-associated MRSA infection in the surgical unit decreased from 1.56 infections per 1,000 patient-days in the 2 years before the intervention to 0.63 infections per 1,000 patient-days in the 4 years after the intervention (a 60% reduction; P = .003). The rate of healthcare-associated MRSA infection in the ICU decreased from 5.45 infections per 1,000 patient-days in the 2 years before to the intervention to 1.35 infections per 1,000 patient-days in the 3 years after the intervention (a 75% reduction; P = .001). The combined estimate for reduction in the incidence of infection after the intervention in the 2 units was 68% (95% confidence interval, 50%–79%; P < .001).nnConclusions. Sustained reduction in the incidence of MRSA infection is possible in a setting where this pathogen is endemic. An industrial systems-engineering approach can be adapted to facilitate consistent and reliable adherence to MRSA infection prevention practices in healthcare facilities.
机译:目的。衡量针对耐甲氧西林的金黄色葡萄球菌(MRSA)预防计划的工业系统工程方法的有效性.nnDesign。干预前后研究nnSetting。匹兹堡退伍军人管理局医院的重症监护病房(ICU)和不是ICU的外科病房。所有患者均接受研究单位nn干预。我们实施了一个由以下4个要素组成的MRSA感染控制程序:(1)对所有患者接触使用标准的预防措施,重点是手的卫生; (2)使用接触预防措施与已知感染或定殖有MRSA的患者互动; (3)使用主动监视文化来识别无症状地定居于MRSA的患者; (4)使用工业系统工程方法,即丰田生产系统,以促进一致且可靠地遵守感染控制程序。手术单元中与医疗保健相关的MRSA感染率从干预前2年的每1,000个患者日1.56感染减少到干预后4年的每1,000个患者日0.63感染(减少60%; P = .003)。重症监护病房中与医疗保健相关的MRSA感染率从干预前的2年中每千名患者天5.45感染减少至干预后3年中每1,000名患者天1.35感染(减少75%; P = .001)。在2个单位进行干预后,减少感染发生率的总估计为68%(95%置信区间,50%–79%; P <.001)。nn结论。在这种病原体为地方性的情况下,可能会持续降低MRSA感染的发生率。可以采用工业系统工程方法来促进医疗机构中对MRSA感染预防实践的一致和可靠遵守。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号