摘要

We evaluated measurement uncertainty and performed internal quality control of an ELISA test for allergens in egg and milk, using control samples. For the evaluation of measurement uncertainty, the following three important factors were identified: 1) Differences in test-kit lots, 2) Different-day reproducibility, 3) Same-time reproducibility. A three-stage nested design was used, and the combined standard uncertainty of the three factors mentioned above was calculated based on the results obtained. Measurement uncertainty was defined as the expanded uncertainty obtained by multiplying the combined standard uncertainty by a coverage factor of two. As a result, the expanded uncertainty of egg was 1.9 mu g/g when the total egg protein concentration was 13.4 mu g/g, and the expanded uncertainty of milk was 1.8 mu g/g when the total milk protein concentration was 13.5 mu g/g. For the internal quality control, we first set the reference range of the measured value of the control sample, using the obtained combined standard uncertainty as an index. Each control sample was then measured for every test, and we concluded that the test was performed without any errors, when the result of the control sample was within the reference range. Second, the measured values of the control samples were plotted on a graph for continuous monitoring. This enabled us to check whether inspection accuracy was maintained. There were no large chronological changes and no major differences between the standard deviations of the control samples and the combined standard uncertainty in egg or milk. Therefore, it was determined that the dispersion was at an acceptable range and inspection accuracy was maintained.
机译:我们评估了测量的不确定性,并使用对照样品对鸡蛋和牛奶中的过敏原进行了ELISA测试的内部质量控制。为了评估测量不确定度,确定了以下三个重要因素:1)测试套件批次之间的差异; 2)不同日期的可重复性; 3)相同时间的可重复性。使用三阶段嵌套设计,并根据获得的结果计算上述三个因素的组合标准不确定度。测量不确定度定义为通过将组合标准不确定度乘以2的覆盖因子而获得的扩展不确定度。结果,当鸡蛋总蛋白浓度为13.4μg/ g时,鸡蛋的膨胀不确定度为1.9μg/ g,当牛奶总蛋白浓度为13.5μg时,牛奶的扩展不确定度为1.8μg/ g。 /G。对于内部质量控制,我们首先使用获得的组合标准不确定度作为指标来设置对照样品测量值的参考范围。然后针对每个测试对每个对照样品进行测量,我们得出的结论是,当对照样品的结果在参考范围内时,进行的测试没有任何错误。其次,将对照样品的测量值绘制在图表上以进行连续监测。这使我们能够检查检查精度是否得以维持。对照样品的标准偏差与鸡蛋或牛奶的组合标准不确定度之间没有较大的时间变化,也没有重大差异。因此,确定分散体在可接受的范围内并且维持检查精度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号