CMA values have been effectively used to evaluate the amount of BI, the brainstem and medulla compression, and the amount of postoperative decompression. However, the reliability and reproducibility of this measurement have yet to be determined. In addition, the information that is available concerning CMA values in normal individuals has been limited to small series of patients. We recruited 200 patients that underwent MR imaging of the craniovertebral junction (CVJ) for unrelated reasons. None of the patients had evidence of abnormalities at the CVJ. Two senior spine surgeons then measured the CMAs of these patients in a blind manner on three separate occasions. The CMA values ranged from 139.0° to 175.5°, with an average value of 158.46°, and a 95% confidence interval from 144.8° to 172.1°. Overall, the CMA had excellent intraobserver repeatability and interobserver reliability. The CMA also had excellent intraobserver repeatability based on both the age and gender of the patients (P = 0.87 and 0.93, respectively). At the same time, the CMA also demonstrated excellent interobserver reliability based on gender (P = 0.97), while good interobserver reliability based on patients age (P = 0.23). No significant correlation between the actual CMA values and the patients’ gender (P = 0.17), age (P = 0.058), or spin-echo series used (P = 0.342). This study demonstrated that CMA values obtained from midsagittal T1 MR images were a highly reliable and repeatable measurement. The data reported in this study can be used as baseline parameters for normal individuals.
机译:CMA值已被有效地用于评估BI量,脑干和延髓压迫以及术后减压量。但是,该测量的可靠性和可重复性尚未确定。此外,有关正常人CMA值的可用信息仅限于少量患者。我们招募了200名因不相关原因而接受颅脑交界处(CVJ)MR成像的患者。没有患者在CVJ处有异常迹象。然后,两名高级脊柱外科医师在三个不同的场合以盲目方式测量了这些患者的CMA。 CMA值的范围为139.0°至175.5°,平均值为158.46°,95%置信区间为144.8°至172.1°。总体而言,CMA具有出色的观察者内可重复性和观察者间可靠性。根据患者的年龄和性别,CMA还具有出色的观察者内部重复性(分别为P = 0.87和0.93)。同时,CMA还显示出出色的基于性别的观察者间可靠性(P = 0.97),而基于患者年龄的良好的观察者间可靠性(P = 0.23)。 CMA的实际值与患者的性别(P = 0.17),年龄(P = 0.058)或所使用的自旋回波序列(P = 0.342)之间无显着相关性。这项研究表明,从矢状T1 MR图像获得的CMA值是高度可靠且可重复的测量。本研究报告的数据可用作正常人的基线参数。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号