Nowadays, the localization of partial discharge (PD) in power transformers by measurement of ultra-high-frequency (UHF) electromagnetic (EM) waves from a PD source is receiving more attention. This method is based on comparing the differences in the arrival times, to antennas in the transformer, of EM waves emitted from the PD source. From the measured UHF signal, and factoring in the influence of the transformer active part on the EM wave propagation, the correct determination of an EM wave arrival time in the localization algorithm is a critical task that influences the accuracy of the UHF PD localization method. Nearly all weak points in the dielectric system of power transformers generate PD. These discharges gradually degrade the insulation, leading to transformer failure. It is possible to detect these defects in the early stages of PD generation by measuring and analyzing the PD data. Suitable maintenance and repair strategies can then be implemented.
机译:如今,通过测量来自局部放电源的超高频(UHF)电磁(EM)波,电力变压器中局部放电(PD)的定位受到越来越多的关注。该方法基于比较从PD源发出的EM波到达变压器天线的到达时间的差异。根据测得的UHF信号,并考虑到变压器有源部件对EM波传播的影响,在定位算法中正确确定EM波到达时间是影响UHF PD定位方法准确性的关键任务。电力变压器介电系统中几乎所有的弱点都会产生局部放电。这些放电会逐渐降低绝缘性能,从而导致变压器故障。通过测量和分析PD数据,可以在PD生成的早期阶段检测这些缺陷。然后可以实施适当的维护和维修策略。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号