We present a new iPad application (app) for a fast assessment of Visual Acuity (VA) and Contrast Sensitivity (CS) whose reliability and agreement was evaluated versus a commercial screening device (Optec 6500). The measurement of VA was programmed in the app in accordance with the Amblyopia Treatment Study protocol. The CS was measured with sinusoidal gratings of four different spatial frequencies: 3, 6, 12 and 18cpd at the same contrast values of the Functional Acuity Contrast Test (FACT) included in the Optec 6500. Forty-five healthy subjects with monocular corrected visual acuities better than 0.2 logMAR participated in the agreement study. Bland-Altman analyses were performed to assess the agreement and Deming regressions to calculate Mean Differences (MDs) and Limits of Agreement (LoAs). Coefficients of reliability were 0.15 logMAR for our method and 0.17 logMAR for the ETDRS testing protocol. For testing the CS, our test showed no statistically significant differences compared with the FACT at any spatial frequency (p > 0.05). The MDs were lower than 0.05 log units for all spatial frequencies.
机译:我们提供了一个新的iPad应用程序(app),用于快速评估视觉敏锐度(VA)和对比度敏感度(CS),与商用筛查设备(Optec 6500)相比,其可靠性和一致性得到了评估。根据弱视治疗研究方案,在应用中对VA的测量进行了编程。 CS的测量使用四个不同空间频率(3、6、12和18cpd的正弦光栅)在与Optec 6500中包含的功能敏锐度对比测试(FACT)相同的对比度值下进行。45位健康受试者的单眼矫正视力优于0.2 logMAR参加了协议研究。进行了Bland-Altman分析以评估一致性,并进行Deming回归以计算平均差异(MDs)和一致性极限(LoAs)。对于我们的方法,可靠性系数为0.15 logMAR,对于ETDRS测试协议,可靠性系数为0.17 logMAR。为了测试CS,我们的测试显示在任何空间频率下与FACT相比均无统计学上的显着差异(p> 0.05)。所有空间频率的MD均低于0.05 log单位。

著录项

  • 来源
    《Displays》 |2016年第9期|15-20|共6页
  • 作者单位

    Departamento de Optica, Universitat de Valencia, 46100 Burjassot, Spain ,Centro de Tecnologlas Fisicas, Universitat Politecnica de Valencia, 46022 Valencia, Spain;

    Departamento de Optica, Universitat de Valencia, 46100 Burjassot, Spain;

    Departamento de Optica, Universitat de Valencia, 46100 Burjassot, Spain;

    Centro de Tecnologlas Fisicas, Universitat Politecnica de Valencia, 46022 Valencia, Spain;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Visual acuity; Contrast sensitivity; Screening; iPad;

    机译:视力对比灵敏度;筛选;的iPad;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号