This paper presents some numerical simulation results of tensile properties of reinforcing bars spliced by grout-filled coupling sleeves under fire conditions to identify the effect of load ratio on fire resistance time of spliced reinforcing bars, which provide a useful base for predicting structural behaviors of pre-cast reinforced concrete buildings in fires. A spliced rebar system investigated in this paper consists of two equal-diameter steel reinforcing bars with 25mm diameter and a straight coupling sleeve with 50mm outer and 45mm inner diameters. As a result, the thickness of grout between steel bars and sleeves are 20mm. Firstly, the temperature distributions in steel bars connected by grout- filled coupling sleeves exposed to ISO 834 standard fire were calculated utilizing finite element analysis software ANSYS. Secondly, the stress changes in heated steel bars connected by grout-filled coupling sleeves under different constant tensile loads were calculated step by step until the rebar system failed due to fire. Thus, the fire resistant time of rebar spliced by grout-filled coupling sleeves under different axial tensile loads can be determined, further, the relationship between fire resistance time and axial tensile loads ratio can could be obtained. Finally, the fire resistant times versus axial tensile load ratios curve of grout-filled splice sleeve rebars exposed to ISO 834 standard fire is presented.
机译:本文给出了灌浆连接套筒拼接的钢筋在火灾条件下抗拉性能的一些数值模拟结果,以识别载荷比对拼接钢筋耐火时间的影响,为预测预应力混凝土的结构性能提供了有用的依据。火灾中浇铸的钢筋混凝土建筑。本文研究的拼接钢筋系统由两个直径为25mm的等直径钢筋和一个外径为50mm,内径为45mm的直形连接套组成。结果,钢筋和套筒之间的灌浆厚度为20mm。首先,利用有限元分析软件ANSYS计算了暴露于ISO 834标准火灾的灌浆连接套管连接的钢筋中的温度分布。其次,逐步计算了在不同的恒定拉伸载荷下,由灌浆的连接套管连接的加热钢筋的应力变化,直到钢筋系统由于火灾而失效。这样,可以确定在不同的轴向拉力条件下,由灌浆的连接套管拼接而成的钢筋的耐火时间,进而可以得到耐火时间与轴向拉力比的关系。最后,给出了暴露于ISO 834标准火中的灌浆式接头套管钢筋的耐火时间与轴向拉伸负荷比的曲线。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号