首页> 外文期刊>Journal of Diabetes Science and Technology >Validation of Plantar Pressure Measurements for a Novel in-Shoe Plantar Sensory Replacement Unit
【24h】

Validation of Plantar Pressure Measurements for a Novel in-Shoe Plantar Sensory Replacement Unit

机译:新型鞋内足底感觉置换装置的足底压力测量验证

获取原文
           

摘要

Background: Research concerning prevention of diabetic foot complications is critical. A novel in-shoe plantar sensory replacement unit (PSRU) has been developed that provides alert-based feedback derived from analyzing plantar pressure threshold measurements in real time. The purpose of this study was to compare the PSRU device to a gold standard pressure-sensing device (GS-PSD) to determine the correlation between concurrent measures of plantar pressure during walking. Methods: The PSRU had an array of eight sensors with a range of 10–75 mm Hg and collected data at 4 Hz, whereas the GS-PSD had 99 sensors with a range of 1–112 mm Hg and collected data at 100 Hz. Based on an a priori power analysis, data were collected from 10 participants (3 female, 7 male) while walking over ground in both devices. The primary variable of interest was the number of data points recorded that were greater than 32 mm Hg (capillary arterial pressure—the minimum pressure reported to cause pressure ulcers) for each of the eight PSRU sensors and corresponding average recordings from the GS-PSD sensor clusters. Intraclass correlation coefficient (2,1) was used to compare data between the two devices. Results: Compared with the GS-PSD, we found good-to-very-good correlations ( r -value range 0.67–0.86; p -value range 0.01–0.05) for six of the PSRU's eight sensors and poor correlation for only two sensors ( r = 0.41, p = .15; r = 0.38, p = .18) when measuring the number of data points recorded that were greater than 32 mm Hg. Conclusions: Based on the results of the present study, we conclude the PSRU provides analogous data when compared with a GS-PSD.
机译:背景:关于预防糖尿病足并发症的研究至关重要。已开发出一种新颖的鞋内足底感觉替换单元(PSRU),该单元可提供基于警报的反馈,该反馈是通过实时分析足底压力阈值测量得出的。这项研究的目的是将PSRU设备与黄金标准压力传感设备(GS-PSD)进行比较,以确定步行过程中同时进行的足底压力测量之间的相关性。方法:PSRU具有八个传感器阵列,其范围为10–75 mm Hg,并以4 Hz的频率收集数据,而GS-PSD具有99个传感器,范围为1–112 mm Hg,并以100 Hz的频率收集数据。根据先验功率分析,在这两种设备中地面行走时,从10位参与者(3位女性,7位男性)收集了数据。感兴趣的主要变量是八个PSRU传感器中的每个传感器记录的数据点数量大于32毫米汞柱(毛细血管动脉压力-报告的引起压疮的最小压力),以及GS-PSD传感器的相应平均记录集群。类内相关系数(2,1)用于比较两个设备之间的数据。结果:与GS-PSD相比,我们发现PSRU的8个传感器中有6个传感器具有良好到非常好的相关性(r值范围为0.67–0.86; p值范围为0.01–0.05),而只有两个传感器的相关性很差(r = 0.41,p = .15; r = 0.38,p = .18)当测量记录的数据点数量大于32 mm Hg时。结论:根据本研究的结果,我们得出结论,与GS-PSD相比,PSRU提供了类似的数据。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号