BackgroundDengue is an important mosquito-borne viral infection that affects millions of persons worldwide. Early diagnosis is necessary to effect appropriate management and decrease mortality. Immunochromatographic tests are advantageous in producing dengue test results within 30?min but these results should be sensitive and specific. In this study we evaluated the diagnostic performance of the SD BIOLINE Dengue DUO? rapid immunochromatographic test kit. A panel of 309 dengue and 30 non-dengue single serum samples characterized by using reference enzyme-linked immunosorbent assays (ELISAs) was used. These samples were received in the virology laboratory for routine testing during a dengue type 1 outbreak between October to December, 2012.ResultsThe overall diagnostic sensitivities of the SD BIOLINE Dengue DUO? rapid testfor IgM, IgG and NSI were 49.3?% (95?% CI: 41.3-57.4), 39.1?% (95?% CI: 33.3-45.2) and 90?% (95?% CI: 82.1-94.7), respectively. The IgM and IgG detection rates were significantly lower than that of the NSI (p?
机译:背景登革热是一种重要的由蚊子传播的病毒感染,感染了全球数百万人。早期诊断对于实现适当的管理并降低死亡率是必要的。免疫色谱法测试可在30分钟内产生登革热检测结果,但这些结果应灵敏而特异。在这项研究中,我们评估了SD BIOLINE Dengue DUO?的诊断性能。快速免疫色谱检测试剂盒。使用一组309个登革热和30个非登革热单血清样品,其特征在于使用参考酶联免疫吸附测定(ELISA)。在2012年10月至2012年12月的1型登革热暴发期间,这些样品已在病毒学实验室接受常规检测。结果SD BIOLINE Dengue DUO?的总体诊断敏感性? IgM,IgG和NSI的快速检测分别为49.3%(95%CI:41.3-57.4),39.1%(95%CI:33.3-45.2)和90%(95%CI:82.1-94.7),分别。 IgM和IgG的检出率显着低于NSI(p <0.001)。但是,将IgM检测与NS1检测或NS1和IgG两者结合使用,灵敏度显着提高(p 0.001)(97.1%(95%CI:92.9-99.2)和98.9%(95%) CI:96.0-99.7)。达到了这些更高的灵敏度,但没有降低特异性。结论本研究表明,将SD BIOLINE Dengue DUO?的两个或多个参数结合在一起即可。快速试剂盒显着提高了登革热病毒感染诊断的敏感性,并支持其在牙买加的应用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号