首页> 外文期刊>Trauma Case Reports >Fixing a fractured arthrodesed hip with rapid prototype templating and minimal invasive plate osteosynthesis
【24h】

Fixing a fractured arthrodesed hip with rapid prototype templating and minimal invasive plate osteosynthesis

机译:快速原型制作和微创钢板固定术修复髋关节骨折

获取原文
           

摘要

CASE: We present an elderly lady with an intertrochanteric fracture of a previously fused hip. A 3D printed model of her pelvis and femur was used for implant templating before surgery. Minimal invasive fixation was performed with a spanning reversed distal femur locking plate without the need for removal of the previous implant. Multiple long locking screws were placed in the supra-acetabular region. The patient had union in 4months, return to function and no complication. Conclusion: The technique allowed us to optimize implant selection and insert screws safely at difficult trajectories using minimal invasive surgery.
机译:案例:我们介绍了一位老年女士,其先前融合的髋关节发生股骨粗隆间骨折。她的骨盆和股骨的3D打印模型在手术前用于植入物模板。使用跨过的反向股骨远端锁定板进行微创固定,无需移除先前的植入物。将多个长的固定螺钉放置在髋臼上区域。病人在四个月内愈合,恢复功能,无并发症。结论:该技术使我们能够优化植入物选择,并使用微创手术安全地在困难的轨道上插入螺钉。