Absolute Myocardial Blood Flow and Flow Reserve Assessed by Gated SPECT with Cadmium-Zinc-Telluride Detectors Using 99mTc-Tetrofosmin: Head-to-Head Comparison with 13N-Ammonia PET

机译:使用99mTc-Tetrofosmin的门控SPECT与镉锌碲化物检测器评估的绝对心肌血流量和血流储备:与13N氨PET的头对头比较

获取原文
           

摘要

id="p-4">Recent advances in SPECT technology including cadmium-zinc-telluride (CZT) semiconductor detector material may pave the way for absolute myocardial blood flow (MBF) measurements by SPECT. The aim of the present study was to compare K1 uptake rate constants as surrogates of absolute MBF and myocardial flow reserve index (MFRi) in humans as assessed with a CZT SPECT camera versus PET. >Methods: Absolute MBF was assessed in 28 consecutive patients undergoing adenosine stress-rest myocardial perfusion imaging (MPI) by 99mTc-tetrofosmin CZT SPECT and 13N-ammonia PET, and MFR was calculated as a ratio of hyperemic over resting MBF. Results from both MPI methods were compared, and correlation coefficients were calculated. The diagnostic accuracy of CZT MFRi to predict an abnormal MFR defined as PET MFR less than 2 was assessed using a receiver-operator-characteristic curve. >Results: Median MBF at rest was comparable between CZT and PET (0.89 [interquartile range (IQR), 0.77-1.00] vs. 0.92 [IQR, 0.78-1.06] mL/g/min; P = not significant) whereas it was significantly lower at stress in CZT than PET (1.11 [IQR, 1.00-1.26] vs. 2.06 [IQR, 1.48-2.56] mL/g/min; P 0.001). This resulted in median MFRi values of 1.32 (IQR, 1.13-1.52) by CZT and 2.36 (IQR, 1.57-2.71) by PET (P 0.001). The receiver-operator-characteristic curve revealed a cutoff for CZT MFRi at 1.26 to predict an abnormal PET MFR yielding an accuracy of 75%. >Conclusion: The estimation of absolute MBF index values by CZT SPECT MPI with 99mTc-tetrofosmin is technically feasible, although hyperemic values are significantly lower than from PET with 13N-ammonia, resulting in a substantial underestimation of MFR. Nevertheless, CZT MFRi may confer diagnostic value.
机译:id =“ p-4”> SPECT技术的最新进展,包括镉锌碲化物(CZT)半导体检测器材料,可为SPECT测量绝对心肌血流(MBF)铺平道路。本研究的目的是比较使用CZT SPECT相机评估的人的 K 1 摄取速率常数,作为人的绝对MBF和心肌血流储备指数(MFRi)的替代物与PET。 >方法:通过 99m Tc-四磷灵CZT SPECT和 13 N氨PET,MFR计算为充血与静息MBF之比。比较两种MPI方法的结果,并计算相关系数。使用接收者-操作者特征曲线评估了CZT MFRi预测定义为PET MFR小于2的异常MFR的诊断准确性。 >结果:静息MBF在CZT和PET之间相当(0.89 [四分位间距(IQR),0.77-1.00]与0.92 [IQR,0.78-1.06] mL / g / min; P =不显着),而在CZT应力下它显着低于PET(1.11 [IQR,1.00-1.26] vs. 2.06 [IQR,1.48-2.56] mL / g / min; P <0.001)。 CZT得出的MFRi中位数为1.32(IQR,1.13-1.52),PET得出的MFRi中位数为2.36(IQR,1.57-2.71)( P <0.001)。接收者-操作者特征曲线显示CZT MFRi的截止值为1.26,以预测异常PET MFR产生的准确度为75%。 >结论:尽管充血值明显低于 13的PET,但充血值明显低于 13m Tc-tetrofosmin的CZT SPECT MPI估计绝对MBF指数值在技术上是可行的 N氨,导致MFR大大被低估。但是,CZT MFRi可能具有诊断价值。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号